高级检索
当前位置: 首页 > 详情页

Clinical observations of EVO-ICL implantation with single incision without viscoelastic agent

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: Implantable Collamer Lens (ICL) Safety Viscoelastic agent Intraocular pressure (IOP) Endothelial Cell Density (ECD)

摘要:
Background To investigate the safety and effectiveness of non-viscoelastic agent technique for EVO-ICL implantation. Methods A total of 181 myopia eyes that underwent non-toric ICL without viscoelastic agent through single incision from Beijing Tongren Hosipital were included. An analysis was conducted on the quantity of haptics that were initially implanted intraoperatively into the posterior chamber. Intraocular pressure (IOP) was evaluated at before and 2 h,24 h,1week,6month after surgery. Anterior chamber volume(ACV), anterior chamber depth(ACD), anterior chamber angle(ACA), pupil diameter(PD) and corneal densitometry density (ECD) were evaluated at before and 24 h postoperatively. Refractive outcomes were investigated at before, 24 h ,7 days and 6months. Vault was evaluated at 24 h ,7 days and 6months. Results The efficacy and safety indices were 1.30 +/- 0.32 and 1.31 +/- 0.32, respectively. Of 181 eyes, 99 eyes received 4 haptics on the first attempt without any adjustment, and 72 eyes received lens alignment without an viscoelastic agent. The success rate of the viscoelastic agent free procedure was 94.5%. Two hours postoperatively, IOP was 17.41 +/- 3.77 mmHg, which was significantly higher than baseline value (t = 8.930, P < 0.000), however there was no significant difference between preoperative IOP and IOP at 1 day ,1 week and 6 months postoperatively. The ECD changed from 2895.52 +/- 253.73 cells/mm2 preoperatively to 2873.66 +/- 244.17 cells/mm2 at 1 day and 2882.63 +/- 239.97 postoperatively, and the difference was not statistically significant (t = 1.811, P = 0.072). The ACA was narrowed by 42% on the first day. Conclusion The pure viscoelastic agent free technique is an efficient and safe way for ICL implantation. It can be a safer method of ICL implantation because of it reduces the risk of complications associated with ocular hypertension at the early postoperative stages. Trial registration Chinese Clinical Trial Registry (ChiCTR2000036335) at August 20, 2020.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2022]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25471 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)