Diurnal variations in corneal biomechanics in healthy young adults

文献详情

资源类型:
Pubmed体系:
机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [2]Eye Center, Xinjiang 474 Hospital, Beijing Road 754, Urimqi, 830000, China. [3]National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [4]State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [5]The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, 325027, China. [6]School of Engineering, University of Liverpool, Liverpool, L69 3GH, UK. [7]Biomedical Research Centre for Ophthalmology, National Institute for Health Research (NIHR), Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK. [8]Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100083, China.
出处:

关键词: Biomechanical metrics Diurnal variations Intraocular pressure Central corneal thickness

摘要:
To assess the diurnal changes in corneal biomechanics in healthy young adults.At Wenzhou Medical University Eye Hospital in China, a prospective case series. Each healthy subject had six Corvis ST examinations, from 10:00 on a first day to 6:00 on the following day, at 4-hour intervals. The data collected included the biomechanically corrected IOP (bIOP), the central corneal thickness (CCT) and six dynamic corneal response (DCR) parameters, namely deformation amplitude (DA), the ratio between DA values at the apex and 2 mm from the apex (DAR2), integrated inverse radius (IIR), the stiffness parameter at first applanation (SP-A1), Corvis biomechanical index (CBI) and the updated stress-strain index (SSIv2). A multilevel model was used to assess the changes in DCR parameters of patients over time during the examination period.Sixty-one subjects were included and intra-operator reproducibility was good for most DCR parameters at the 6 time points. DA, DAR2, IIR and CBI showed small fluctuations during the 24-hour cycle with mean values of 0.1, 0.16, 0.34, and 0.04 units, respectively, while SP-A1 showed higher variations averaging 20.57 units and SSIv2 had the least fluctuation within 0.10 units during 24-hour cycle. After correcting for the effects of CCT and bIOP, the diurnal fluctuations in IIR, CBI and SSIv2 were not statistically significant, unlike the fluctuations in DA, DAR2 and SP-A1, which remained significant.Compared with the DA, DAR2, IIR and CBI, SP-A1 was more affected while SSIv2 was the less affected by the diurnal variations and associated corneal edema.© 2025. The Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
第一作者:
第一作者机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [2]Eye Center, Xinjiang 474 Hospital, Beijing Road 754, Urimqi, 830000, China.
共同第一作者:
通讯作者:
通讯机构: [1]National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [3]National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [4]State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, WenZhou Medical University, Wenzhou, 325027, China. [5]The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, 325027, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25463 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)