高级检索
当前位置: 首页 > 详情页

Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [2]Shijiazhuang Aier Eye Hosp, Ctr Refract Surg, Shijiazhuang 050000, Hebei, Peoples R China [3]Cent South Univ, Aier Sch Ophthalmol, Changsha 410000, Hunan, Peoples R China
出处:
ISSN:

关键词: intraocular lens IOL power calculation formula SMILE equivalent IOL power Lenstar 900

摘要:
AIM: To compare the Barrett True-K formula with other formulas integrated in Lenstar 900 to predict intraocular lens (IOL) power after small-incision lenticule extraction (SMILE). METHODS: A theoretical prospective study was performed to predict the ratio of equivalent IOL power before and after SMILE using the SRK/T (Sanders, Retzlaff, Kraff/ theoretical), Holladay 1, Haigis, and Barrett True-K formulas and compare the stability of their predictions. The study included 54 eyes (54 cases) with a manifest refraction spherical equivalent (MRSE) of -4.99 +/- 1.45 D. They were divided into two groups: 27 eyes with axial length of 24-26 mm in Group A, and 27 eyes with axial length >26 mm in Group B. All subjects enrolled in this study were examined with the Lenstar 900 before and 6mo after SMILE including measurements of axial length, corneal curvature, and anterior chamber depth (ACD). RESULTS: The prediction of equivalent IOL power of the two groups was more stable for the Barrett True-K formula, especially in long axial length eyes (Group B). The respective percentages for the SRK/T, Holladay 1, Haigis, and Barrett True-K formulas were 7.4%, 7.4%, 85.19%, and 88.89% for a margin of error within 0.5 D; 25.92%, 51.84%, 100%, and 100% for a margin of error within 1.0 D in Group A; 33.33%, 40.74%, 44.44%, and 81.48% for a margin of error within 0.5 D; and 44.44%, 59.26%, 66.66%, and 92.59% for a margin of error within 1.0 D in Group B. The respective percentages for Barrett True-K formulas were 100% for a margin of error within 2.0 D in Group B. CONCLUSION: Theoretically, the Barrett True-K formula provides more stable predictions than other formulas for cataract eyes after SMILE.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2018]版:
Q4 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [2]Shijiazhuang Aier Eye Hosp, Ctr Refract Surg, Shijiazhuang 050000, Hebei, Peoples R China [3]Cent South Univ, Aier Sch Ophthalmol, Changsha 410000, Hunan, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [*1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Ophthalmology & Visual Sciences Key Lab, Capital Medical University, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)