高级检索
当前位置: 首页 > 详情页

Optical coherence tomography-based deep learning algorithm for quantification of the location of the intraocular lens

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Inst Ophthalmol,Beijing,Peoples R China [2]Chinese Acad Sci, Inst Automat, State Key Lab Management & Control Complex Syst, Beijing, Peoples R China [3]Hebei Univ Technol, Coll Artificial Intelligence & Data Sci, Tianjin, Peoples R China [4]Capital Med Univ,Beijing Tongren Hosp,Beijing Key Lab Ophthalmol & Visual Sci,Beijing Tongren Eye Ctr,Beijing,Peoples R China
出处:
ISSN:

关键词: Intraocular lens optical coherence tomography deep learning position

摘要:
Background: Cataract surgery has been recently developed from sight rehabilitating surgery to accurate refractive surgery. The precise concentration of intraocular lens (IOL) is crucial for postoperative high visual quanlity. The three-dimentional (3D) images of ocular anterior segment captured by optial coherence tomography (OCT) make it possible to evaluate the IOL position in 3D space, which provide insights into factors relavant to the visual quanlity and better design of new functional IOL. The deep learning algorithm potentially quantify the IOL position in an objective and efficient way. Methods: The region-based fully convolutional network (R-FCN) was used to recogonize and delineate the IOL configuration in 3D OCT images. Scleral spur was identified automatically. Then the tilt angle of the IOL relative to the scleral spur plane along with its decentration with respect to the pupil were calculated. Repeatability and reliability of the method was evaluated by the intraclass correlation coefficient. Results: After improvement, the R-FCN network recognition efficiency of IOL configuration reached 0.910. The ICC of reliability and repeatability of the method is 0.867 and 0.901. The average tilt angle of the IOL relative to scleral spur is located in 1.65 +/- 1.00 degrees. The offsets dx and dy occurring in the early X and Y directions of the IOL are 0.29 +/- 0.22 and 0.33 +/- 0.24 mm, respectively. The IOL offset distance is 0.44 +/- 0.33 mm. Conclusions: We proposed a practical method to quantify the IOL postion in 3D space based on OCT images and assisted by an algorithm.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 2 区 医学
小类 | 2 区 医学:研究与实验 2 区 肿瘤学
最新[2023]版:
JCR分区:
出版当年[2018]版:
Q2 MEDICINE, RESEARCH & EXPERIMENTAL Q2 ONCOLOGY
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Inst Ophthalmol,Beijing,Peoples R China
共同第一作者:
通讯作者:
通讯机构: [4]Capital Med Univ,Beijing Tongren Hosp,Beijing Key Lab Ophthalmol & Visual Sci,Beijing Tongren Eye Ctr,Beijing,Peoples R China [*1]Capital Med Univ,Beijing Tongren Hosp,Ophthalmol Dept,Dong Jiao Min Xiang 1,Beijing,Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)