Assessment of Corneal Biomechanical Properties with Inflation Test Using Optical Coherence Tomography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China [2]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University.Beijing Ophthalmology & Visual Sciences Key Laboratory.National Engineering Research Center for Ophthalmology, Beijing 100730, China [3]School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China [4]Department of Ophthalmology, Chinese PLA General Hospital, Beijing 100853, China
出处:
ISSN:

关键词: Deformation Elasticity Imaging Stiffness Viscoelasticity Young's modulus

摘要:
Biomechanical properties are important for the cornea to maintain its normal shape and function. There is still a need to develop better methods for accurate measurement of corneal mechanical properties. In this study, we propose to introduce the optical coherence tomography (OCT) in inflation test for the imaging of corneal deformation in order to measure its biomechanical properties. Ten cornea-mimicking silicone phantoms with different stiffness and five fresh porcine corneas were tested using the proposed method. Intra-ocular pressure was changed from 10 to 90 mmHg using two different loading rates to observe the pressure-apex displacement relationship and calculate the apparent stiffness of the corneas. Stiffness of the corneal phantoms obtained by the inflation test ranged from 0.2 to 1 MPa, which was highly consistent with the results from the mechanical tensile test (y = 0.70x, p < 0.001). The porcine corneas showed highly viscoelastic behavior with obvious hysteresis in inflation. The apparent stiffness of the porcine corneas was 0.63 +/- 0.07 and 1.05 +/- 0.08 MPa with loading rates of 3.3 and 33 mmHg/min, respectively. Mapping of corneal surface displacement was also generated for both the phantom and porcine corneas. This study showed that it is feasible to incorporate the high resolution OCT imaging in inflation test to measure the biomechanical properties of the cornea.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 工程技术
小类 | 2 区 工程:生物医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 工程:生物医学
JCR分区:
出版当年[2016]版:
Q1 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China [*1]School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China [*2]Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23710 今日访问量:0 总访问量:1289 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)