Assessment of macular function in patients with idiopathic Epiretinal membrane by multifocal Electroretinography: correlation with visual acuity and optical coherence tomography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital MedicalUniversity. Beijing Ophthalmology and Visual Sciences Key Laboratory,Beijing, China [2]Department of Ophthalmology, Yantai Yuhuangding Hospital,Affiliated Hospital of Medical College, Qingdao University, Yantai, Shandong,China [3]Department of Ophthalmology, Beijing Electric Power Hospital,Beijing, China [4]Department of Ophthalmology, Kailuan General Hospital,Tangshan, China
出处:
ISSN:

关键词: Electroretinography Epiretinalmembrane Optical coherence tomography

摘要:
Background: This study evaluates the macular function changes in patients with idiopathic macular epiretinal membrane (ERM) by multifocal electroretinography (mfERG) and their correlations with visual acuity and central macular thickness (CMT) by optical coherence tomography (OCT). Methods: Twenty eyes of 20 patients with ERM underwent OCT and mfERG examinations. The response amplitude densities and implicit times of mfERG were compared to the control fellow eyes. Correlation analyses among visual acuity, central macular thickness and mfERG values in the central two concentric rings were performed. Results: The mfERG P1 response amplitude densities in ring 1-2 and P1 implicit time in ring1 were significantly changed in epiretinal membrane eyes compared with controls (P < 0.05). Multivariate stepwise linear regression analyses showed LogMAR visual acuity was significantly correlated with CMT (P = 0.004), and also with the P1 amplitude density in ring 1 (P = 0.002). CMT showed significant correlation with P1 implicit time in ring 2 (P = 0.013). Conclusions: The mfERG abnormalities show macular function changes and correlate with visual acuity and central macular thickness in eyes with ERM. In first-order mfERG responses, P1 wave changes may be a sensitive functional measurement for ERM patients.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2015]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital MedicalUniversity. Beijing Ophthalmology and Visual Sciences Key Laboratory,Beijing, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)