Reduction on OFF-responses of Electroretinogram in Monkeys with Long-term High Intraocular Pressure

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Ophthalmol & Visual Sci Key Lab,Dept Ophthalmol,Beijing Tongren Eye Ctr,Beijing 100730,Peoples R China [2]Capital Med Univ,Beijing Inst Ophthalmol,Beijing Tongren Hosp,Beijing Tongren Eye Ctr,Beijing 100730,Peoples R China
出处:
ISSN:

关键词: Electroretinogram OFF-responses Monkey Intraocular Pressure Retinal Pathway

摘要:
Background: There are ON-and OFF-pathways in the normal vertebrate retina. Short-and long-flash electroretinogram (ERG) are suitable methods to observe the function of ON-and OFF-pathways in vivo, respectively. It is clear that high intraocular pressure (IOP) might cause dysfunction of cone-dominated photopic negative response (PhNR) in monkeys with high IOP in ON-pathway. However, whether cone-dominated OFF-responses are also affected is less known. The aim of this study was to observe photopic OFF-responses of ERG in monkeys with high IOP. Methods: Nine monkeys were involved in the experiment from January 2006 to December 2016. High IOP was induced in the right eye by laser coagulation of the mid-trabecular meshwork in five monkeys. Six years after the laser coagulation, both short-and long-flash of the photopic ERG were recorded. Stimulus light was red flashes superimposed on a blue background. Four normal monkeys were examined under the same ERG protocols as controls. Paired t-test was used to compare the difference of each ERG parameter between the lasered eye and the fellow eye. Analysis of variance (ANOVA) with Tukey adjustment was adopted to calculate the differences among the lasered eye, the fellow eye, and the eyes of normal monkeys. Results: The mean amplitude of a-wave (11.73 +/- 2.05) and PhNR (8.67 +/- 2.44) in lasered eyes was significantly lower than that of a-wave (21.47 +/- 3.15) and PhNR (22.05 +/- 3.42) in fellow eyes (P = 0.03 and P 0.01, respectively) in response to short flash. The mean amplitude of d-wave (1.60 +/- 0.59) and i-wave (3.13 +/- 0.64) was significantly reduced in the lasered eyes than that of d-wave (4.01 +/- 0.56) and i-wave (8.79 +/- 1.75) in the fellow eyes (P = 0.02 and P = 0.02, respectively) in response to long flash. Conclusions: Reduced OFF-responses are recorded in monkeys with high IOP when dysfunction of photoreceptor is involved. The reduced OFF-responses to long-flash stimulus show evidence of anomalous retinal circuitry in glaucomatous retinopathy.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2015]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Ophthalmol & Visual Sci Key Lab,Dept Ophthalmol,Beijing Tongren Eye Ctr,Beijing 100730,Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Ophthalmol & Visual Sci Key Lab,Dept Ophthalmol,Beijing Tongren Eye Ctr,Beijing 100730,Peoples R China [*1]Beijing Tongren Eye Center,Beijing Ophthalmology and Visual Science Key Lab,Beijing Tongren Hospital,Capital Medical University,Beijing 100730,China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21173 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)