PurposeTo describe the use of a newly developed side-viewing catheter probe to provide the cross-sectional images of collector channel entrance (CCE), achieved by swept-source optical coherence tomography (SS-OCT). MethodsA side-viewing SS-OCT catheter probe was developed that has a core probe diameter of 0.15mm and an outer diameter of 0.25mm, for the purpose of imaging CCEs within eye globe. Cadaver eyes harvested from swine and human were used to demonstrate its feasibility. For porcine eyes, the probe imaged the CCE by accessing the region of the aqueous plexus (AP) as well as along the inner wall (IW) of the trabecular meshwork (TM). For human eyes, the CCE images were captured by placing the probe within the lumen of the Schlemm's canal (SC) and along its IW. ResultsWith the optical coherence tomography (OCT) catheter probe, the CCE is well delineated as optically empty areas within the highly scattering sclera. In porcine eyes, images captured in the region of the AP demonstrate a large cavity with delicate tissue strands around the probe. The CCE can be identified at the outer margin of the AP. When imaged along the IW, the TM is discernable but difficult to be distinguished from the AP. In the human limbal regions, when placed within the lumen of the SC, the catheter probe fully occupies the potential space. TM is highly compact. The CCE can be identified at the outer wall of the SC. When imaged along the IW of TM, the SC and CCE can be identified. ConclusionThe intraocular SS-OCT catheter probe is feasible to provide the CCE images, indicating useful clinical applications to assist glaucoma surgery.
基金:
National Science and Technology Support Project, China [2011BAI16B0]
第一作者机构:[1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ophthalmol, Beijing, Peoples R China
通讯作者:
通讯机构:[3]Capital Med Univ,Beijing Tongren Hosp,Dept Ophthalmol,1 Dongjiaominxiang,Beijing 100730,Peoples R China[*1]Department of Ophthalmology,Beijing Tongren Hospital Capital Medical University No 1 Dongjiaominxiang Dongcheng District 100730 Beijing,China
推荐引用方式(GB/T 7714):
Xin Chen,Chen Xiaoya,Li Meng,et al.Imaging collector channel entrance with a new intraocular micro-probe swept-source optical coherence tomography[J].ACTA OPHTHALMOLOGICA.2017,95(6):602-607.doi:10.1111/aos.13415.
APA:
Xin, Chen,Chen, Xiaoya,Li, Meng,Shi, Yan,Wang, Huaizhou...&Wang, Ningli.(2017).Imaging collector channel entrance with a new intraocular micro-probe swept-source optical coherence tomography.ACTA OPHTHALMOLOGICA,95,(6)
MLA:
Xin, Chen,et al."Imaging collector channel entrance with a new intraocular micro-probe swept-source optical coherence tomography".ACTA OPHTHALMOLOGICA 95..6(2017):602-607