Positive End-Expiratory Pressure Effect of 3 High-Flow Nasal Cannula Devices

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Union Med Coll Hosp, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China [2]Peking Union Med Coll, Dept Clin Med, Beijing, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Dept Crit Care Med, Beijing, Peoples R China
出处:
ISSN:

关键词: PEEP effect HFNC device AIRVO 2 system ventilator

摘要:
BACKGROUND: High-flow nasal cannula (HFNC) is supposed to provide additional PEEP compared with conventional oxygen therapy. However, the exact determinants of this PEEP effect are unclear. We investigated the factors that might affect the PEEP and compared PEEP performance among 3 HFNC devices. METHODS: Three available HFNC devices were evaluated: the AIRVO 2 device and 2 mechanical ventilators (SV300 and Monnal T75). A device consisting of a test lung (5600i) and an airway model (AMT(IE)) was used to simulate spontaneous breathing. The flows ranged from 0 to their maximum flow with an interval of 10 L/min. The pressures were measured at 4 sites (nasopharynx, supraglottis, carina, and lung) under compliances of 50 and 100 mL/cm H2O and tidal volume of 300, 500, and 700 mL with the mouth closed or open. The influencing factors were determined by multiple linear regression. The sum of squares reduction test was used to compare working curves of PEEP effect among 3 devices. Pairwise comparisons were conducted by using Tukey's multiple comparisons test within an overlap of flow from 0 to 50 L/min. RESULTS: A quadratic curved relationship between PEEP and flow was observed (coefficients were 8.97 x 10(-3) for flow and 4.79 x 10(-4) for a quadratic element of flow, respectively) but evanished when the mouth was open. The PEEP increased along with lung compliance (coefficient was 2.58 x 10(-3)). Despite the difference in working curves, both the mechanical ventilators performed slightly better than the AIRVO 2 device at higher flows (40 and 50 L/min). CONCLUSIONS: The mouth status, flow, and compliance were the 3 major influencing factors of PEEP effect, whereas performance of the 2 mechanical ventilators was slightly superior to that of the AIRVO 2 device at higher flows.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 危重病医学 4 区 呼吸系统
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 危重病医学 4 区 呼吸系统
JCR分区:
出版当年[2015]版:
Q3 CRITICAL CARE MEDICINE Q3 RESPIRATORY SYSTEM
最新[2023]版:
Q2 CRITICAL CARE MEDICINE Q2 RESPIRATORY SYSTEM

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Beijing Union Med Coll Hosp, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China
通讯作者:
通讯机构: [1]Beijing Union Med Coll Hosp, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China [*1]Medical Intensive Care Unit, Peking Union Medical College Hospital, 1 Shuai Fu Yuan, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23418 今日访问量:3 总访问量:1279 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)