高级检索
当前位置: 首页 > 详情页

Dynamic Change of Optical Quality in Patients With Dry Eye Disease

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol, Beijing, Peoples R China [2]Quinze Vingts Natl Ophthalmol, Dept Ophthalmol 3, Paris, France [3]Versailles St Quentin En Yvelines Univ, Versailles, France [4]Quinze Vingts Natl Ophthalmol Hosp, Ctr Clin Invest, INSERM 503, Paris, France [5]INSERM, U968, Paris, France [6]Univ Paris 06, Inst Vis, UMR S 968, Paris, France [7]CNRS, UMR 7210, Paris, France
出处:
ISSN:

关键词: dry eye disease optical quality double-pass system scattering

摘要:
PURPOSE. To evaluate the dynamic changes of optical quality in patients with dry eye disease (DED) by using a double-pass system. METHODS. Fifty-six patients with DED and 35 control subjects were included in this study. Each patient underwent an evaluation of the ocular surface, using the Ocular Surface Disease Index, tear film breakup time (TBUT), corneal and conjunctival staining (Oxford scale), and Schirmer I test. Using the tear film analysis program of the Optical Quality Analysis System, we recorded the objective scatter index (OSI) every 0.5 seconds within a 20-second period with the subjects asked to blink freely. Several parameters were established to evaluate the dynamic alterations of optical quality and the effects of blinks: OSI standard deviation (SD), Delta OSI, Delta OSI/time, blinking change (BC), blinking frequency (BF), and tolerant limitation (TL). RESULTS. Patients with DED had significant alterations of optical quality compared to control subjects. The Delta OSI, Delta OSI/time, BC, and BF were significantly higher and TL was significantly lower in DED patients than controls. Furthermore, the Delta OSI and Delta OSI/time were also significantly higher in patients with severe DED than patients with mild disease. In univariate analysis, both TBUT and corneal staining were correlated with Delta OSI, Delta OSI/time, and BC. In multivariate analysis, Delta OSI/time was correlated to the corneal staining score. CONCLUSIONS. The double-pass system allowed the monitoring of the dynamic changes of optical quality in patients with DED. Optical quality should be evaluated in patients with DED because these alterations cannot be determined from the classical DED clinical tests.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2013]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol, Beijing, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol, Beijing, Peoples R China [*1]Beijing Tongren Hosp, Beijing Inst Ophthalmol, 17 Hou Gou Lane,Chong Nei St, Beijing 100005, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)