Higher Iodine Concentration Enables Radiation Dose Reduction in Coronary CT Angiography.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China. [2]Department of Cardiology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China. [3]Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China.
出处:
ISSN:

关键词: Radiation dose reduction Contrast media High concentration iodinated agent Image quality Coronary computed tomography angiography

摘要:
To test whether higher iodine concentration together with higher noise level could lead to a further dose reduction in an already low dose coronary CT angiography (CCTA) protocol without comprising image quality.One hundred eighty patients with suspected coronary artery disease (CAD) were randomly assigned into three groups: (a) conventional dose (CD) group, 100 kV with a noise index (NI) of 25 and iohexol (350 mg I/ml); (b) low dose (LD) group, 80 kV with a NI of 25 and iohexol (350 mg I/ml); (c) further low dose (FLD) group, 80 kV with a NI of 30 and iomeprol (400 mg I/ml). The volume and injection rate of contrast medium were fixed at 60 ml and 5 ml/s. The radiation dose (volume CT dose index [CTDIvol], dose length product [DLP], and effective dose [ED]) were recorded. For image quality, both quantitative (enhancement, noise, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) and qualitative indices were assessed.Compared to the CD group, ED was reduced by 16% and 42% in the LD and FLD groups, respectively (p < 0.05). Qualitative analysis showed no significant difference among the 3 groups (p > 0.05), while quantitative analysis revealed significantly higher attenuation in the LD and FLD groups. Signal-to-noise ratios and CNRs of the LD and FLD groups were significantly higher except for the CNR at the left circumflex branch of the FLD group (p < 0.05).Increasing iodine concentration and noise level may further reduce the radiation dose by 26% on top of a 16% reduction from 100 kV to 80 kV without image quality compromise.Copyright © 2020 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2019]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23459 今日访问量:6 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)