Validation of the phenol red thread test in a Chinese population

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China. [2]Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University and Capital Medical University, Beijing, China.
出处:
ISSN:

关键词: Phenol red thread test Dry eye Tear volume Repeatability Reproducibility

摘要:
To investigate the validation of phenol red thread (PRT) test in a Chinese population by evaluating the intraobserver repeatability and interobserver reproducibility, determining correlations between the PRT test and other dry eye disease (DED) parameters including tear meniscus height (TMH) and Schirmer I test, and testing the accuracy of diagnosing DED when using the PRT test alone.A total of 108 eyes were involved in this prospective and diagnostic study, and were divided into two groups (with and without DED). Each subject underwent a series of ocular surface examinations, including Ocular Surface Disease Index (OSDI) questionnaire, non-invasive tear breakup time (NIBUT), tear meniscus height (TMH) assessment, PRT test, fluorescein tear breakup time (FBUT), corneal fluorescein staining and Schirmer I test.In the experimental group and the control group, the intra-class correlation coefficients (ICCs) of the repeatability were 0.747 and 0.723, respectively (all P < 0.05). The ICCs of the reproducibility in both groups were 0.588 and 0.610, respectively (all P < 0.05). The PRT test correlated weakly with the Schirmer I test and the tear meniscus height, with Spearman coefficients of 0.385 and 0.306, respectively (all P < 0.05). The PRT test is available to diagnose DED, with an area under the curve of 0.806 and a Youden index of 0.556 at the cutoff point of 8.83 mm.The PRT test can provide patients a comfortable, timesaving and less irritating approach to screening and diagnosing DED compared to Schirmer I test.© 2023. The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2021]版:
Q3 OPHTHALMOLOGY
最新[2024]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China.
共同第一作者:
通讯作者:
通讯机构: [1]Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, 100730, China. [2]Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University and Capital Medical University, Beijing, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:29117 今日访问量:0 总访问量:1619 更新日期:2025-10-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)