高级检索
当前位置: 首页 > 详情页

A Practical Study of Diagnostic Accuracy Scoliosis Screenings of Middle School Students by a Trained Nurse With a Smartphone Versus a Spine Surgeon With a Scoliometer

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Orthoped, Sch Med, Shanghai, Peoples R China
出处:
ISSN:

关键词: Adams forward bending test (FBT) adolescent idiopathic scoliosis (AIS) angle of trunk rotation (ATR) lumbar curve school screening scoliometer scoliosis screening smartphone spinal deformity thoracic curve

摘要:
Study Design. Cross-sectional. Objective. This study aimed to assess the accuracy of smartphone-aided diagnosis of scoliosis by a trained nurse compared with scoliometer-based diagnosis by a spine surgeon. Summary of Background Data. Many assessments have been developed to estimate the reliability of smartphone-aided measurements in diagnosing scoliosis. However, clinical studies assessing the accuracy of smartphone-aided diagnosis with radiographs or scoliometers are scarce. Methods. A total of 2702 grade 7 students (mean age 13.56 yrs, range 13-15) at 10 middle schools were first screened with a smartphone by a trained nurse from the orthopedics department. Approximately half a year later, most of the students underwent a chest x-ray examination as part of a compulsory medical examination. Students with suspicious findings in either the first screen or the chest x-ray were recommended to a scoliosis clinic for single-blind tests, such as a forward bending test (FBT) and an analysis of the angle of trunk rotation (ATR) with a scoliometer, performed by an experienced spine surgeon. Finally, the Cobb method was conducted with full-spine radiographs to serve as the gold standard. Results. The agreement between the first screening by the nurse and the second test by the spine surgeon was low in cases with a Cobb angle <10 degrees (kappa = 0.128 [0.04-0.22], P = 0.035) and fair in cases with a Cobb angle >10 degrees (kappa = 0.349 [0.19-0.50], P < 0.001). The results of receiver operating characteristic (ROC) curve analysis also suggested that these two tests were similar in their ability to diagnose scoliosis. However, when the Cobb angle cutoff was adjusted to 15 degrees, the latter had markedly better diagnostic ability than the former. Overall, the sensitivity of the smartphone screening was not acceptable for recognizing scoliosis. Conclusion. This study revealed that smartphone-aided screening for scoliosis is risky.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 2 区 骨科 3 区 临床神经病学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 骨科 3 区 临床神经病学
JCR分区:
出版当年[2018]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY
最新[2024]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Orthoped, Sch Med, Shanghai, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Shanghai Jiao Tong Univ, Tongren Hosp, Dept Orthoped, Sch Med, Shanghai, Peoples R China [*1]Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, 1111 XianXia Rd, Shanghai 200336, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:28514 今日访问量:5 总访问量:1589 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)