The Value of Thyroid Ultrasound Computer-Aided Diagnosis System in the Evaluation of Thyroid Nodules With Concurrent Hashimoto's Thyroiditis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China
出处:
ISSN:

关键词: computer-aided diagnosis Hashimoto's thyroiditis thyroid neoplasms ultrasound

摘要:
Objective To investigate the value of computer-aided diagnosis (CAD) system in assessing thyroid nodules concurrent with Hashimoto's thyroiditis (HT). Methods Totally 148 patients with 193 thyroid nodules were enrolled. A radiologist assessed the nodules using a thyroid ultrasound CAD system. Additionally, the nodules were evaluated by one experienced radiologist alone, and one training radiologist without and with CAD assistance. The diagnostic performance was compared between the CAD system and the experienced radiologist, and the training radiologist without and with CAD assistance. Results The CAD system demonstrated a similar sensitivity to that of the experienced radiologist in diagnosing thyroid cancers (89.8% versus 92.4%, P > .05). The specificity and accuracy of the CAD system were lower than that of the experienced radiologist in assessing the nodules with diffusedly altered glands (specificity, 60.0% versus 81.7%, P = .007; accuracy, 77.5% versus 88.1%, P = .011). With CAD assistance, the training radiologist had improved sensitivity and accuracy that increased to 87.9% and 86.8% in classifying nodules with sonographically evident HT (both P = .012). Conclusion The CAD system has comparable sensitivity, but lower specificity compared with the experienced radiologist in diagnosing thyroid malignancies concurrent with HT. For a radiologist with less experience, the CAD system can help improve the diagnostic performance by increasing sensitivity and accuracy in assessing thyroid nodules with diffusely altered parenchyma.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 声学 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
JCR分区:
出版当年[2020]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ACOUSTICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China [*1]1 Dong Jiao Min Xiang St, Beijing 100073, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)