高级检索
当前位置: 首页 > 详情页

Comparative analysis of the morphological and biomechanical properties of normal cornea and keratoconus at different stages

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Chinese Peoples Liberat Army Gen Hosp, Dept Ophthalmol, Beijing 100853, Peoples R China [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Inst Ophthalmol,Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [3]Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing 100730, Peoples R China [4]Capital Med Univ, Beijing Tongren Hosp, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: Keratoconus Corneal morphology Corneal biomechanics Corneal visualization Scheimpflug technology

摘要:
Purpose To compare the morphological and biomechanical properties of normal cornea and keratoconus at different stages. Methods A total of 408 patients (517 eyes) with keratoconus were included in this study. According to the Topographic Keratoconus (TKC) grading method, keratoconus was divided into stage I (TKC = 1, 130 eyes), stage II (TKC = 1-2, 2, 164 eyes), stage III (TKC = 2-3, 3, 125 eyes) and stage IV (TKC = 3-4, 4, 98 eyes). A total of 158 normal subjects (158 eyes) were recruited as the normal group. The corneal morphological parameters and biomechanical parameters were obtained with Scheimpflug tomography (Pentacam) and corneal visualization Scheimpflug technology (Corvis ST), and the receiver operating characteristic (ROC) curves were drawn. Results Each corneal morphological and most biomechanical parameters of the keratoconic eyes were significantly different from those of the normal eyes in this study (p < 0.001). ROC curve demonstrated that most parameters in this study showed high efficiency in diagnosing keratoconus (the area under the ROC (AUC) was > 0.9), with the Belin-Ambrosio deviation (BAD-D) and Tomographic and Biomechanical Index (TBI) showing higher efficiency. The efficiency of BAD-D and TBI was high in differentiating keratoconus at different stages (AUC > 0.963). The comparison of ROC curves of keratoconus at different stages did not reveal statistically significant differences for TBI. Conclusion BAD-D and TBI can effectively diagnose stage I keratoconus. Moreover, the efficiency of TBI is the same in diagnosing keratoconus at all stages, while the diagnostic efficiency of other parameters increases with the increase in keratoconus stages.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2019]版:
Q4 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Chinese Peoples Liberat Army Gen Hosp, Dept Ophthalmol, Beijing 100853, Peoples R China
通讯作者:
通讯机构: [2]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Inst Ophthalmol,Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [3]Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing 100730, Peoples R China [4]Capital Med Univ, Beijing Tongren Hosp, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)