机构:[1]Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China首都医科大学附属北京同仁医院首都医科大学附属同仁医院[2]Department of Ophthalmology, Chinese PLA General Hospital, Beijing, China
PurposeTo evaluate the biomechanical properties of the cornea using Corneal Visualization Scheimpflug Technology (CorVis ST, Oculus) in eyes with primary open-angle glaucoma (POAG) and normal control eyes. MethodsA comparative cross-sectional study that included 42 patients with POAG and 60 normal control subjects matched for intraocular pressure (IOP) and central corneal thickness (CCT). IOP was measured with a Goldmann applanation tonometer (GAT). Corneal tomography and biomechanical parameters were measured with Pentacam (Oculus) and CorVis ST, respectively. Corneal biomechanical properties were compared between groups, and the associations between corneal biomechanical parameters and ocular characteristics were evaluated. Receiver operating characteristic (ROC) curves were used to establish a cut-off value for the biomechanical parameters. ResultsThe following parameters of the CorVis ST showed a significant difference between eyes with POAG and normal eyes: first applanation velocity (V-in), second applanation time (A-time(2)), peak distance (PD) and deformation amplitude (DA). In the univariate analysis, DA was negatively correlated with IOP in both groups. For all biomechanical parameters, the areas under the ROC curve were <0.80 and thus did not reach a good level of predictive accuracy for detecting POAG. ConclusionCorVis ST offers an alternative method for measuring corneal biomechanical properties. Eyes with POAG exhibit a faster V-in, longer A-time(2), lower DA and longer PD than do IOP- and CCT-matched normal control eyes. The biomechanical parameters of the CorVis ST cannot readily be used for diagnosis of POAG in the individual patient.
基金:
National Natural Science Foundation of ChinaNational Natural Science Foundation of China (NSFC) [81271052]
第一作者机构:[1]Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China[2]Department of Ophthalmology, Chinese PLA General Hospital, Beijing, China
共同第一作者:
通讯作者:
通讯机构:[2]Department of Ophthalmology, Chinese PLA General Hospital, Beijing, China[*1]Department of Ophthalmology Chinese PLA General Hospital Beijing 100853 China
推荐引用方式(GB/T 7714):
Tian Lei,Wang Dajiang,Wu Ying,et al.Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes[J].ACTA OPHTHALMOLOGICA.2016,94(5):e317-e324.doi:10.1111/aos.12672.
APA:
Tian, Lei,Wang, Dajiang,Wu, Ying,Meng, Xiaoli,Chen, Bing...&Huang, Yifei.(2016).Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes.ACTA OPHTHALMOLOGICA,94,(5)
MLA:
Tian, Lei,et al."Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes".ACTA OPHTHALMOLOGICA 94..5(2016):e317-e324