高级检索
当前位置: 首页 > 详情页

Establishment and application of an immunoassay for the simultaneous detection of IgG and its subtype IgG4 autoantibodies against M-type phospholipase A2 receptor

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Zhejiang Sci Tech Univ, Coll Life Sci & Med, Hangzhou, Peoples R China [2]Nanjing Med Univ, Wuxi Clin Med Coll, Affiliated Wuxi Childrens Hosp, Wuxi, Jiangsu, Peoples R China [3]Jiangsu Inst Nucl Med, Wuxi, Jiangsu, Peoples R China [4]Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Shanghai, Peoples R China [5]Nanjing Med Univ, Wuxi Peoples Hosp Affiliated, Wuxi, Jiangsu, Peoples R China [6]Zhejiang Prov Peoples Hosp, Hangzhou, Peoples R China
出处:
ISSN:

关键词: Time-resolved fluorescence immunoassay M-type phospholipase A2 receptor IgG IgG4 Idiopathic membranous nephropathy

摘要:
Background: The renal biopsy is an accurate and reliable gold standard for membranous nephropathy (MN) diagnosis. However, it is an invasive procedure involving the risk of hemorrhage or infection. Thus, an alter-native approach that can facilitate the effective diagnosis and treatment monitoring of idiopathic membranous nephropathy (IMN) is urgently needed. Methods: We established a dual-labeled time-resolved fluoroimmunoassay (TRFIA) to simultaneously detect phospholipase A2 receptor (PLA2R)-IgG4 and PLA2R-IgG antibodies. Utilizing this assay, we determined the ratio of autoantibodies in the serum of patients with different kidney diseases and normal controls. Results: The sensitivity of TRFIA for detecting anti-PLA2R-IgG and anti-PLA2R-IgG4 was 0.12 mu g/mL and 0.001 mu g/mL, respectively. Human IgA did not interfere with the assay. Compared to anti-PLA2R-IgG alone, the pos-itive rate of IMN could be increased from 86.5 % to 91.7 % through the combined use of anti-PLA2R-IgG4 and the PLA2R-IgG4/IgG ratio. In contrast, the false-positive rates for the detection of IgA nephropathy, lupus ne-phropathy, diabetic nephropathy, and minimal change nephropathy decreased from 25 to 50 % to 0 %. Conclusions: The dual-labeled PLA2R-IgG4/IgG-TRFIA for simultaneous detection of anti-PLA2R-IgG4 and anti-PLA2R-IgG will contribute to improved accuracy of IMN diagnosis.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2019]版:
Q2 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Zhejiang Sci Tech Univ, Coll Life Sci & Med, Hangzhou, Peoples R China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)