Digital versus slit-beam marking for toric intraocular lenses in cataract surgery

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Ophthalmology & Visual Science Key Laboratory, Capital Medical University, No.1 Dongjiaomin lane, Dongcheng District, Beijing, 100730, China
出处:
ISSN:

关键词: Corneal astigmatism Marking IOL misalignment Toric IOL Callisto eye image-guided system Cataract surgery

摘要:
To compare the visual outcomes of digital and slit-beam manual marking for toric intraocular lenses (IOL) in cataract surgery.Single-center, Beijing Tongren Hospital, China.Retrospective study.All patients with cataracts and regular corneal astigmatism greater than 0.75 diopters (D) underwent cataract surgery and astigmatism correction between June 2019 and June 2020. To mark the target axis of the toric IOL and the location of the incision, intraoperative digital marking was used by Callisto eye image-guided system in one group, while preoperative manual slit-beam marking was used in the other group. Uncorrected and best-corrected spectacle visual acuity, refraction, toric IOL axis, total higher order aberrations, coma, spherical aberration, and trefoil were evaluated at 1, 4, and 12 weeks postoperatively.Seventy-two eyes of 58 patients were included. At 3 months after surgery, the mean residual refractive cylinder was 0.42 ± 0.45D in the digital group and 0.39 ± 0.40D in the manual group (P = 0.844). There were no significant differences between groups in spherical equivalent refraction, uncorrected and best-corrected spectacle visual acuity, or the parameters of vector analysis. All toric IOL alignment errors were within 10° of the intended axis, and among them, about 42% of eyes in the digital group and 61% of eyes in the manual group had a rotation of 0-2° (P = 0.038). Trefoil in the manual group decreased postoperatively compared with the digital group (P = 0.012). Other aberration analyses did not reveal any statistical differences between groups.Accurate slit-beam manual marking and digital image-guided marking are equally effective for toric IOL alignment.© 2022. The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2020]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Ophthalmology & Visual Science Key Laboratory, Capital Medical University, No.1 Dongjiaomin lane, Dongcheng District, Beijing, 100730, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)