高级检索
当前位置: 首页 > 详情页

Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Wuhan Univ, Wuhan Hosp 3, Tongren Hosp, Dept Radiol, Wuhan 430060, Peoples R China [2]GE Healthcare, Computed Tomog Res Ctr, Beijing, Peoples R China [3]Wuhan Univ, Wuhan Hosp 3, Tongren Hosp, Dept Orthoped, Wuhan 430060, Peoples R China
出处:
ISSN:

关键词: Radiation Dose Iodixanol Contrast Dose Contrast-Enhanced Chest CT Lung Cancer ASIR Image Quality

摘要:
Background: Contrast-enhanced chest computed tomography (CT) is useful for the detection and follow-up of patients with lung cancer. However, reaching balance between diagnostic image quality, radiation dose, and iodixanol dose is a cause of concern.Objectives: To investigate the clinical value of adaptive statistical iterative reconstruction (ASIR) in reducing the iodixanol content and radiation dose during contrast-enhanced chest CT scan for patients diagnosed with lung masses/nodules based on the analysis of image quality.Patients and Methods: This prospective study was conducted on 80 patients diagnosed with nodules or masses, who required contrast-enhanced chest CT scans. The experimental group (n = 40) was subjected to iohexol at a high concentration (350 mgI/L) with a tube voltage of 120 kVp and a filter back projection (FBP) reconstruction algorithm. The comparison group (n = 40) was subject to iodixanol at a lower concentration (270 mgI/L) with a tube voltage of 100 kVp and ASIR (blending ratio, 40%). The radiation dose and total iodixanol content, as well as subjective and objective evaluations of image quality, were analyzed and compared.Results: The two groups obtained non-significantly different subjective scores for five structures detected in the lung window and five structures detected in the mediastinal window, as well as the overall image (P> 0.05 for all). Both the two-group images obtained diagnosis-acceptable scores (>= 3 points) on displays of 10 structures and overall image quality. The mean CT value of vessels (100 kVp vs. 120 kVp: 314.90 +/- 23.42 vs. 308.93 +/- 21.40; P > 0.05), standard deviation (13.03 +/- 0.88 vs. 12.83 +/- 0.90; P > 0.05), and contrast-tonoise ratio (20.77 +/- 2.20 vs. 20.36 +/- 1.94; P > 0.05) were not significantly different between two groups. However, the CT dose index, dose-length product, effective dose, and total iodine dose were reduced by 27.58%, 36.65%, 36.59%, and 22.86% in the 100-kVp groupConclusion: The ASIR showed great potential in reducing the radiation dose and iodine contrast dose, while maintaining good image quality and providing strong confidence for the diagnosis of lung cancer.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2020]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Wuhan Univ, Wuhan Hosp 3, Tongren Hosp, Dept Radiol, Wuhan 430060, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Wuhan Univ, Wuhan Hosp 3, Tongren Hosp, Dept Radiol, Wuhan 430060, Peoples R China [3]Wuhan Univ, Wuhan Hosp 3, Tongren Hosp, Dept Orthoped, Wuhan 430060, Peoples R China [*1]Department of Orthopedics,Wuhan Third Hospital,Wuhan, 430060, China [*2]Department of Radiology,Wuhan Third Hospital,Wuhan, 430060, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21173 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)