高级检索
当前位置: 首页 > 详情页

Analysis of the relationship between lens morphology and aberrations in patients with myopia: a cross-sectional study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
出处:
ISSN:

关键词: Lens morphology Aberration Myopic CASIA2 OPD- scan III

摘要:
To investigate the relationship between lens morphology and aberrations in patients with myopia.This cross-sectional study included 155 patients with myopia in their right eyes. Spherical power and cylindrical power were achieved by cycloplegic autorefraction. The eyes were divided into three groups for analysis based on their spherical equivalent (SE) values. The 4 mm and 6 mm ocular and internal aberrations were measured using the OPD-scan III. Lens parameters were measured using CASIA2, including lens thickness (LT), radius of anterior/posterior lens surface curvature (RAL/RPL), lens decentration (DEC), and lens tilt (TILT). The differences of lenticular parameters and aberration parameters among the three groups analyzed with ANOVA or Kruskal Wallis test. Pearson correlation or Spearman correlation analysis was performed to evaluate the relationships between the lens parameters and aberrations. A p value < 0.05 indicated statistical significance.The difference in LT, RAL, DEC and TITL among the three groups was statistically significant (p < 0.05). And there were differences among differences in internal high-order aberrations, spherical aberration, and coma aberration(p < 0.05).Spherical power was positively correlated with LT and TITL (p < 0.05) and negatively correlated with DEC, RAL, and RPL (p < 0.05). Cylindrical power was positively correlated with LT (p < 0.05) and negatively correlated DEC (p < 0.05); The lenticular parameters (LT, RAL, DEC, and TILT) were mainly correlated with the ocular and internal spherical aberration. LT and DEC were correlated with ocular and internal higher-order aberrations and coma aberration.DEC and LT were the main factors affecting aberrations in patients with myopia.© 2023. The Author(s), under exclusive licence to Springer Nature B.V.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2021]版:
Q3 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23410 今日访问量:0 总访问量:1276 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)