高级检索
当前位置: 首页 > 详情页

Predicting the impact of femtosecond-assisted arcuate keratotomy combined with tri-planar clear corneal incisions on astigmatism in implantable collamer lens surgery: one-year follow-up

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Aier Intech Eye Hospital, Panjiayuan Plaza, #12 Panjiayuan Nanli, Chaoyang District, Beijing, China. [2]Beijing Ophthalmology and Science Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. [3]Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, No. 1 Dongjiaomin Xiang, Dongcheng District, Beijing, 100730, China.
出处:
ISSN:

关键词: Femtosecond-assisted Limbal relaxing incisions Steep-Meridian Tri-planar clear corneal incisions Implantable collamer lens

摘要:
To investigate the factors associated with and impact on the femtosecond-assisted (FS-assisted) limbal relaxing incision (LRI) combined with the steep-meridian tri-planar clear corneal incision (TCCI) to reduce astigmatism in patients undergoing Implantable Collamer Lens (ICL) surgery.Retrospective case series. The study reviewed patients with ICL surgery combined with FS-assisted LRIs paired with steep-meridian TCCIs. Correlation analysis examined the relationship between independent variables, including preoperative characteristics (intraocular pressure, corneal thickness, axial length, et al.), TCCI, and LRI surgical parameters. The predictors of surgically induced astigmatism (SIA) were determined using individual-level analysis and accounting for inter-eye correlation with the generalized estimating equation (GEE).The study enrolled 69 patients, with 114 eyes (55 right and 59 left). The mean spherical equivalent (SEQ) was - 10.29 ± 2.99D and - 9.99 ± 2.72D for the right and left eye, respectively, while the mean preoperative corneal astigmatism was - 1.54 ± 0.47D and - 1.54 ± 0.46D for the right and left eyes, respectively. After 12 months of follow-up, univariate analysis revealed significant correlations between SIA and intraocular pressure (IOP), astigmatism type, TCCI position (degree), peripheral corneal thickness (PCT), LRI arc incision diameter, post depth (%), and angle, respectively (P = 0.046, 0.016, 0.039, 0.040, 0.009, 0.000, 0.000). Multivariate analysis using GEE demonstrated that axial length (AL), astigmatism type, LRI arc diameter, and angle were independent predictors of SIA (P = 0.000, 0.005, 0.029, 0.000).The type of astigmatism and axial length were independent factors that affected SIA when modifying the LRI arc diameter and angle through FS-assisted steep-meridian TCCI paired with LRI in ICL surgery.© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2022]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Beijing Aier Intech Eye Hospital, Panjiayuan Plaza, #12 Panjiayuan Nanli, Chaoyang District, Beijing, China. [2]Beijing Ophthalmology and Science Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. [3]Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, No. 1 Dongjiaomin Xiang, Dongcheng District, Beijing, 100730, China.
通讯作者:
通讯机构: [1]Beijing Aier Intech Eye Hospital, Panjiayuan Plaza, #12 Panjiayuan Nanli, Chaoyang District, Beijing, China. [2]Beijing Ophthalmology and Science Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. [3]Beijing Tongren Hospital, Beijing Tongren Eye Center, Capital Medical University, No. 1 Dongjiaomin Xiang, Dongcheng District, Beijing, 100730, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25471 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)