determination of Anticyclic Citrullinated Peptide Based on Biotin-Streptavidin-Amplified Time-Resolved Fluoroimmunoassay

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shanghai Jiao Tong Univ, Sch Med, Shanghai Tongren Hosp, Shanghai 200030, Peoples R China [2]Nanjing Med Univ, Affiliated Wuxi Peoples Hosp, Wuxi 214023, Peoples R China [3]Zhejiang Univ, Coll Med, Affiliated Hosp 1, Dept Lab Med, Hangzhou 310003, Zhejiang, Peoples R China
出处:
ISSN:

关键词: cyclic citrullinated peptide rheumatoid arthritis time-resolved fluoroimmunoassay

摘要:
Background: A rapid and sensitive time-resolved fluoroimmunoassay (TRFIA) based on the biotin-streptavidin amplification system was developed for the determination of anticyclic citrullinated peptide (anti-CCP). Methods: Europium-labeled streptavidin derivatives combined with europium and anhydride of diethylene triamine pentaacetic acid were used to label streptavidin, biotin was coupled with rabbit antihuman IgG to form a biotin-anti-human IgG bridge between streptavidin-europium and the anti-CCP antibody in the immunoassay. The anti-CCP assay was carried out by measuring the fluorescence of Eu3+-streptavidin at 615 nm. Results: The presented method produced a wide linear range from 0.58 to 9,463 U/ml, while it was only 591.4-18.48 U/ml when using an ELISA kit, and featured a detection limit up to 0.5 U/ml for anti-CCP. The values determined by the biotin-streptavidin-TRFIA and ELISA correlated well (R-2 = 0.8927). The method was applied to determine anti-CCP in serum samples with satisfied recoveries of 96.45-104.63%. Conclusion: The assay results obtained by the present method showed that biotin-streptavidin-amplified TRFIA improve the traditional ELISA kit for anti-CCP detection. Therefore, it offers a better alternative immunoassay in rheumatoid arthritis management. (C) 2014 Wiley Periodicals, Inc.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2013]版:
Q3 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Shanghai Jiao Tong Univ, Sch Med, Shanghai Tongren Hosp, Shanghai 200030, Peoples R China
通讯作者:
通讯机构: [2]Nanjing Med Univ, Affiliated Wuxi Peoples Hosp, Wuxi 214023, Peoples R China [3]Zhejiang Univ, Coll Med, Affiliated Hosp 1, Dept Lab Med, Hangzhou 310003, Zhejiang, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)