高级检索
当前位置: 首页 > 详情页

Sound-localisation performance in patients with congenital unilateral microtia and atresia fitted with an active middle ear implant

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
出处:
ISSN:

关键词: Sound localisation Microtia and atresia Conductive Hearing loss unilateral Vibrant soundbridge

摘要:
Objective This study assessed the safety and sound-localisation ability of the Vibrant Soundbridge (VSB) (Med-EL, Innsbruck, Austria) in patients with unilateral microtia and atresia (MA). Methods This was a single-centre retrospective research study. Twelve subjects with unilateral conductive hearing loss (UCHL) caused by ipsilateral MA were recruited, each of whom underwent VSB implantation and auricular reconstruction. The bone-conduction (BC) threshold was measured postoperatively, and the accuracy of sound localisation was evaluated at least 6 months after surgery. Horizontal sound-localisation performance was investigated with the VSB activated and inactivated, at varying sound stimuli levels (65, 70 and 75 dB SPL). Localisation benefit was analysed via the mean absolute error (MAE). Results There was no statistical difference in mean BC threshold of impaired ears measured preoperatively and postoperatively. When compared with VSB-inactivated condition, the MAE increased significantly in unilateral MA patients in the VSB-activated condition. Besides, sound-localisation performance worsened remarkably when sound was presented at 70 dB SPL and 75 dB SPL. Regarding the side of signal location, the average MAE with the VSB device was much higher than that without the VSB when sound was from the normal-hearing ear. However, no significant difference was observed when sound was located from the impaired ear. Conclusion This study demonstrates that in patients with unilateral MA, the VSB device does not affect inner-ear function. Sound-localisation ability is not improved, but deteriorated at follow-up. Our results suggest that the VSB-aided localisation abilities may be related to the thresholds between the ears, plasticity of auditory system and duration of use of VSB.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 3 区 耳鼻喉科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 耳鼻喉科学
JCR分区:
出版当年[2019]版:
Q2 OTORHINOLARYNGOLOGY
最新[2023]版:
Q2 OTORHINOLARYNGOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25477 今日访问量:1 总访问量:1499 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)