高级检索
当前位置: 首页 > 详情页

MP-3 measurement of retinal sensitivity in macular hole area and its predictive value on visual prognosis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang, Beijing 100730, Peoples R China [2]Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China [3]Hebei United Univ, Kailuan Gen Hosp, Dept Ophthalmol, Tangshan, Peoples R China
出处:
ISSN:

关键词: Idiopathic macular hole The MP-3 microperimetry Visual prognosis Vitrectomy

摘要:
Purpose To explore a measuring method for retinal sensitivity in macular hole area by Microperimeter-3 (MP-3) and evaluate its predictive value on visual prognosis. Methods This was a case series study including 44 eyes of 44 patients with idiopathic macular hole. Retinal sensitivity inside and 0.5 degree outside the macular hole margin was measured, and its mean value was defined as macular hole sensitivity (MHS). Best-corrected visual acuity (BCVA), minimum diameter of macular hole (MD), IS/OS defect diameter, retinal sensitivity in 8 degrees and 2 degrees were also recorded preoperatively and 4 months after operation. Results All macular holes were closed after surgery. BCVA was significantly improved from 1.06 +/- 0.39 at baseline to 0.31 +/- 0.24 at 4 months postoperatively (P < 0.001). Meanwhile, MHS was also significantly improved from 12.02 +/- 3.74 dB at baseline to 20.72 +/- 4.00 dB at 4 months postoperatively (P < 0.001). MD, preoperative IS/OS defect diameter, preoperative BCVA, preoperative retinal sensitivity in 8 degrees and 2 degrees, and preoperative MHS were all correlated with postoperative BCVA at 4 months, but only preoperative MHS showed liner relationships to postoperative BCVA at 4 months by multivariate stepwise linear analysis. Conclusions Macular hole sensitivity by MP-3 could reflect the change of central retinal function after successful macular hole surgery. Compared to preoperative retinal sensitivity in 8 degrees and 2 degrees, preoperative macular hole sensitivity is a better predictor for visual prognosis.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2017]版:
Q4 OPHTHALMOLOGY
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang, Beijing 100730, Peoples R China [2]Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang, Beijing 100730, Peoples R China [2]Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)