Comparison of corneal curvature parameters obtained from two different instruments-Pentacam and VX120

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: corneal curvature anterior chamber depth Pentacam VX120 interclass correlation coefficients

摘要:
AIM: To explore whether the same corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 have a good consistency and can replace each other. METHODS: This study enrolled 140 eyes of 70 patients ranging in age from 19 to 53y. All eyes underwent a comprehensive ophthalmologic examination including an anterior segment analysis with the VX120 system (Visionix-Luneau Technologies, Chartres, France) and Pentacam (Oculus Optikgerate GmbH) respectively. The comparison on corneal curvature parameters was done between Pentacam and VX120 using clustered signed rank test; the interclass correlation coefficients (ICC) with 95% confidence intervals (CI) was calculated for each parameter between Pentacam and VX120; the Bland-Altman plot of each parameter was supplemented. RESULTS: The anterior corneal curvature measured by VX120 was Ks: 44.00 +/- 1.78 D, KsAt: 89.45 +/- 22.18, Kf: 42.84 +/- 1.58 D, KfAt: 93.91 +/- 79.34; which measured by Pentacam was Ks: 43.80 +/- 1.82 D, KsAt: 91.17 +/- 21.40, Kf: 42.61 +/- 1.64 D, KfAt: 91.16 +/- 78.69. There was statistical difference between Pentacam and VX120 for anterior corneal curvature parameter (P<0.001). The posterior corneal curvature measured by VX120 was Ks: -6.42 +/- 1.23 D, KsAt: 91.00 +/- 23.45, Kf: -5.85 +/- 1.24 D, KfAt: 95.93 +/- 79.11; which measured by Pentacam was Ks: -6.44 +/- 0.32 D, KsAt: 92.24 +/- 11.75, Kf: -6.01 +/- 1.05 D, KfAt: 74.43 +/- 80.64. There was statistical difference between Pentacam and VX120 for posterior corneal curvature parameters (P<0.001). Anterior chamber depth (ACD) measured by Pentacam and VX120 was statistically different. Pentacam and VX120 achieved high consistency only on corneal anterior surface, including Ks and Kf. The ICCs were 0.96 (95%CI: 0.95, 0.97) and 0.95 (95%CI: 0.94, 0.97) respectively. For other corneal surface curvature parameters, all ICCs of between Pentacam and VX120 were below 0.87. Bland-Altman plots indicated of low consistency of corneal surface curvature parameters measured by Pentacam and VX120. CONCLUSION: The corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 were statistically different. Data measured by Pentacam and VX120 is not suggested to replace each other, mixing data measured by Pentacam and VX120 together is not suggested either.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2017]版:
Q4 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing 100730, Peoples R China [*1]Beijing Institute of Ophthalmology ,Beijing Tongren Eye Center ,Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing 100730, Peoples R China [*1]Beijing Institute of Ophthalmology ,Beijing Tongren Eye Center ,Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21166 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)