Repeatability and Reproducibility of Quantitative Assessment of the Retinal Microvasculature Using Optical Coherence Tomography Angiography Based on Optical Microangiography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ CSCD-C

机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Tongren Eye Ctr,Dept Ophthalmol,Beijing 100730,Peoples R China [2]Beijing Key Lab Ophthalmol & Visual Sci, Beijing 100730, Peoples R China [3]Capital Med Univ,Beijing Tongren Hosp,Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol,Beijing 100005,Peoples R China [4]Beijing Key Lab Ophthalmol & Visual Sci, Beijing 100005, Peoples R China [5]Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
出处:
ISSN:

关键词: Optical coherence tomography angiography Repeatability Reproducibility Macular blood flow Retinal superficial capillary Vascular quantification

摘要:
Objective The aim of this study was to determine the repeatability and reproducibility of optical coherence tomography angiography (OCTA) based on optical microangiography (OMAG) measurements of macular vessels in normal eyes. Methods In this prospective cohort study, 40 eyes of 40 healthy volunteers underwent repeated OCTA (Cirrus HD-OCT 5000 angiography system, Carl Zeiss Meditec, Inc.) scans on two separate visit days. On each visit day, the eyes were scanned three times. The following parameters were used to quantitatively describe the OCTA images of the superficial vascular network: vessel area density (VAD), vessel skeleton density (VSD), vessel diameter index (VDI), vessel perimeter index (VPI), vessel complexity index (VCI), flux, and foveal avascular zone (FAZ). Coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for evaluating intravisit and intervisit repeatability, as well as interobserver reproducibility. Results The measurements showed high repeatability [CVs <= 4.2% (intravisit) and <= 4.6% (intervisit)] and interobserver reproducibility (ICCs >= 0.923) for all parameters. Conclusion This study demonstrated good repeatability and reproducibility of OCTA based on OMAG for the measurement of superficial vessel parameters in normal eyes.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 3 区 环境科学与生态学
小类 | 3 区 环境科学 3 区 公共卫生、环境卫生与职业卫生
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 环境科学 4 区 公共卫生、环境卫生与职业卫生
JCR分区:
出版当年[2016]版:
Q2 ENVIRONMENTAL SCIENCES Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
最新[2023]版:
Q2 ENVIRONMENTAL SCIENCES Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Tongren Eye Ctr,Dept Ophthalmol,Beijing 100730,Peoples R China [2]Beijing Key Lab Ophthalmol & Visual Sci, Beijing 100730, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ,Beijing Tongren Hosp,Beijing Tongren Eye Ctr,Dept Ophthalmol,Beijing 100730,Peoples R China [2]Beijing Key Lab Ophthalmol & Visual Sci, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25463 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)