高级检索
当前位置: 首页 > 详情页

Parapapillary Gamma Zone and Axial Elongation-Associated Optic Disc Rotation: The Beijing Eye Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol,Beijing Tongren Hosp, Beijing, Peoples R China [2]Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Heidelberg, Germany [3]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Intraocular Tumor Diag & Treatmen, Beijing Tongren Eye Ctr, Beijing, Peoples R China
出处:
ISSN:

关键词: parapapillary gamma zone optic disc optic disc rotation parapapillary atrophy Bruch's membrane myopia Beijing Eye Study

摘要:
PURPOSE. The parapapillary gamma zone has been defined as the parapapillary region without Bruch's membrane. We examined which morphologic parameters are associated with the presence and size of the parapapillary gamma zone. METHODS. Using fundus photographs and spectral-domain optical coherence tomographic images of the optic nerve head in the population-based Beijing Eye Study, we determined parapapillary gamma zone width, macular Bruch's membrane length, optic disc-fovea distance, the angle of horizontal optic disc rotation, the angle of vertical optic disc rotation, and the ratio of the vertical-to-horizontal disc diameter. RESULTS. The study included 2068 individuals with a mean age of 63.0 +/- 9.0 years (range, 50-91 years), and mean axial length was 23.2 +/- 1.0 mm (range, 18.96-28.87 mm). In multivariate analysis, larger width of parapapillary gamma zone was associated with more marked vertical optic disc rotation (P < 0.001; standardized correlation coefficient beta, 0.15; nonstandardized correlation coefficient B, 0.02; 95% confidence interval [CI], 0.02, 0.03), more marked horizontal optic disc rotation (P = 0.02; beta, 0.05; B, 0.01; 95% CI, 0.001, 0.01), longer axial length (P = 0.01; beta, 0.07; B, 0.02; 95% CI, 0.01, 0.04), longer horizontal optic disc diameter (P = 0.02; beta, 0.05; B, 0.06; 95% CI, 0.01, 0.12), longer disc-fovea distance (P < 0.001; beta, 0.25; B, 0.22; 95% CI, 0.18, 0.27), higher degree of fundus tessellation (P = 0.03; beta, 0.17; B, 0.04; 95% CI, 0.03, 0.0), and thinner subfoveal choroidal thickness (P < 0.001; beta, -0.13; B, 0.000; 95% CI, -0.001, 0.000). Parapapillary gamma zone width was not significantly associated with macular Bruch's membrane length (P = 0.72), disc-fovea angle (P = 0.62), age (P = 0.62), or sex (P = 0.46). CONCLUSIONS. The parapapillary gamma zone was associated with an axial elongation-induced rotation of the optic disc mainly around the vertical disc axis, leading to a stretching of the temporal peripapillary scleral flange. Because macular Bruch's membrane length was independent of axial elongation, it leaves the temporal parapapillary region with an uncovered Bruch's membrane (i.e., parapapillary gamma zone develops).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2014]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol,Beijing Tongren Hosp, Beijing, Peoples R China [2]Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Heidelberg, Germany
共同第一作者:
通讯作者:
通讯机构: [3]Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Intraocular Tumor Diag & Treatmen, Beijing Tongren Eye Ctr, Beijing, Peoples R China [*1]Beijing Tongren Hosp, Beijing Tongren Eye Ctr, 1 Dong Jiao Min Lane, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23425 今日访问量:5 总访问量:1281 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)