Evaluation of a magnetic particles-based chemiluminescence enzyme immunoassay for Golgi protein 73 in human serum

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Medical Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, PR China [2]Beijing Ranos Medical Technology Co., Ltd, Beijing, PR China [3]Department of Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, PR China [4]Beijing Hotgen Biotechnology Co., Ltd., Beijing, PR China
出处:
ISSN:

关键词: Golgi protein 73 Chemiluminescence enzyme immunoassay Evaluation Magnetic particles Hepatocellular carcinoma

摘要:
Background: Golgi protein 73 (GP73) is regarded as a potential serum biomarker for early diagnosis of hepatocellular carcinoma (HCC). We developed a rapid magnetic particles-based chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of serum GP73. Methods: Fluorescein isothiocyanate (FITC) and alkaline phosphatase (ALP) were used to label 2 different monoclonal antibodies to GP73. Serum GP73 was captured with labeled antibodies and formed a sandwiched immunoreaction. The magnetic particles (MPs) coated with anti-FITC antibody were used as a means of separation of the GP73 protein from other serum proteins. After adding the enzyme substrate solution, the relative light unit (RLU) was measured. A MPs-CLEIA for serum GP73 was established and evaluated. Results: The RLU was directly proportional to the concentration of GP73. The method linearity was 5-600 mu g/I. Limit of the blank was 2.19 mu g/I. The intra- and inter-assay imprecision was <3% and <5%, respectively. The average recoveries were between 95% and 105%. The proposed method showed a good correlation with a commercial ELISA assay (r = 0.983, p < 0.001). We also evaluated the efficiency of serum GP73 measurement for the diagnosis of HCC using this assay. The area under the receiver operating characteristic curve was 0.822 (95% CI, 0.73-0.89), and the sensitivity and specificity, with cut-off value of 115.6 mu g/I, were 75.4% and 92.1%, respectively. Conclusions: The proposed method demonstrates an acceptable performance for quantifying serum GP73. This assay could be appropriate for routine use in clinical laboratories. (C) 2015 Elsevier B.V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 3 区 医学
小类 | 2 区 医学实验技术
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2013]版:
Q1 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Department of Medical Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, PR China
通讯作者:
通讯机构: [1]Department of Medical Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing, PR China [*1]Department of Medical Laboratory, Beijing Tongren Hospital, Capital Medical University, No. 1, Dongjiaominxiang Street, Dongcheng District, Beijing 100730, PR China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23661 今日访问量:1 总访问量:1286 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)