机构: [1]City Univ London, Moorfields Eye Hosp, NIHR Biomed Res Ctr Ophthalmol, London EC1V 0HB, England [2]City Univ London, UCL Inst Ophthalmol, London EC1V 0HB, England [3]City Univ London, Dept Optometry & Visual Sci, London EC1V 0HB, England [4]Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing, Peoples R China [5]Dalhousie Univ, Dept Ophthalmol & Visual Sci, Halifax, NS, Canada
出处:
ISSN:

关键词: neuroretinal rim area Heidelberg retina tomography comparison time series reference plane

摘要:
Purpose:To investigate the agreement between neuroretinal rim area (RA) measurements using the Heidelberg Retina Tomograph I (HRT Classic) and Heidelberg Retina Tomograph II (HRT II). To compare apparent RA changes in follow-up series of HRT II topographies when using either an HRT Classic or HRT II mean topography as baseline.Design:Cross-sectional study and no-change, short time series study.Participants:Forty-three ocular hypertensive and 31 primary open angle glaucoma subjects.Methods:Five HRT Classic and 5 HRT II examinations were acquired from 1 eye of each subject, across 2 visits within 6 weeks. For the cross-sectional study, follow-up RA measurements from HRT Classic and HRT II were compared, using the same HRT Classic mean topography as the baseline. The linear rates of RA change were compared in 2 short time series with either an HRT Classic or an HRT II mean topography as baseline, and 4 follow-up HRT II mean topographies. Intervals between topographies were arbitrarily set at 1 year for meaningful comparisons of rates. Rates of RA change over time were calculated by linear regression. Separate analyses were performed using 3 available reference planes (RP).Main Outcome Measures:Global and sectoral RA measurements in HRT Classic and HRT II mean topographies; linear rates of RA change.Results:HRT Classic minus HRT II mean differences (95% limits of agreement) were 0.09 (-0.17, 0.35) mm(2), 0.09 (-0.13, 0.32) mm(2), and 0.11 (-0.24, 0.46) mm(2) for the Moorfields, 320 mu m, and standard RPs, respectively (P<0.001 for all RPs, Wilcoxon rank sum test). In the time series, the mean differences (95% limits of agreement) of RA rates of change (HRT Classic baseline minus HRT II baseline) were -0.01 (-0.06, 0.03) mm(2)/y, -0.01 (-0.06, 0.04) mm(2)/y, and -0.0(2) (-0.09, 0.05) mm(2)/y using the Moorfields, 320 mu m, and standard RPs, respectively.Conclusion:Although HRT software is backward-compatible, follow-up RA measurements made in the same eye using HRT Classic and HRT II devices display statistically and clinically meaningful systematic differences when HRT Classic topographies are used as a baseline.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
JCR分区:
出版当年[2011]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]City Univ London, Moorfields Eye Hosp, NIHR Biomed Res Ctr Ophthalmol, London EC1V 0HB, England [2]City Univ London, UCL Inst Ophthalmol, London EC1V 0HB, England [4]Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing, Peoples R China
通讯作者:
通讯机构: [1]City Univ London, Moorfields Eye Hosp, NIHR Biomed Res Ctr Ophthalmol, London EC1V 0HB, England [2]City Univ London, UCL Inst Ophthalmol, London EC1V 0HB, England [*1]Moorfields Eye Hosp, Glaucoma Res Unit, 162 City Rd, London EC1V 2PD, England
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)