高级检索
当前位置: 首页 > 详情页

Peripheral Anterior Synechia Reduce Extent of Angle Widening After Laser Peripheral Iridotomy in Eyes With Primary Angle Closure

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab 1, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [2]Wenzhou Med Coll, Sch Optometry & Ophthalmol, Affiliated Eye Hosp, Wenzhou, Zhejiang, Peoples R China [3]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China [4]Handan 3rd Hosp, Dept Ophthalmol, Handan, Hebei Province, Peoples R China [5]Queensland Eye Inst, Brisbane, Qld, Australia [6]Univ Queensland, Brisbane, Qld 4072, Australia
出处:
ISSN:

关键词: peripheral anterior synechia laser peripheral iridotomy primary angle closure gonioscopy ultrasound biomicroscopy

摘要:
Purpose: To quantify the effect of laser peripheral iridotomy (LPI) on angle widening in primary angle closure with and without peripheral anterior synechia (PAS).Patients and Methods: Prospective hospital-based study of 44 consecutive patients (69 eyes) with primary angle closure. Comprehensive ophthalmic examination and ultrasound biomicroscopy were performed at enrollment and 2 weeks following LPI. The following angle parameters: angle opening distance, trabecular-iris angle, and angle recess area were obtained. On the basis of the presence of PAS, angle quadrants were divided into 3 groups: group A comprised quadrants in PAS-negative eyes; group B, the unaffected quadrants in PAS-positive eyes; and group C, the quadrants with PAS in PAS-positive eyes. Correlation between PAS and angle width was determined and changes in angle parameters following LPI were compared between groups.Results: Sixty-six eyes of 42 patients (31 eyes with PAS) were available for analysis. Groups A, B, and C provided 140, 66, and 58 quadrants, respectively, for analysis. There was a moderate negative correlation between angle width changes (angle opening distance, trabecular-iris angle, angle recess area) after LPI and PAS extent at baseline (r=-0.46 to -0.39; P<0.01). The change in angle width was significantly different between groups A and B compared to group C (P<0.01); there was no difference between groups A and B.Conclusions: Changes in anterior chamber angle following LPI were inversely correlated with presence of PAS. Quadrants unaffected by PAS can be expected to widen as much as in eyes with only appositional closure. In quadrants with PAS the ultrasound biomicroscopy parameters did not change following LPI.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2011]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab 1, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [3]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab 1, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China [*1]Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab 1, Beijing Tongren Eye Ctr, Dong Jiao Min Xiang St, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25463 今日访问量:0 总访问量:1498 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)