Comparative study of anterior segment measurement with Pentacam and anterior segment optical coherence tomography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Tongren Eye Ctr, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: ophthalmological diagnostic techniques reproducibility of results tomography optical coherence/methods

摘要:
Objective: To evaluate the repeatability of central corneal thickness (CCT), anterior chamber volume (ACV), and central anterior chamber depth (CACD) measurements obtained using a Pentacam rotating Scheimpflug camera, and to examine their agreement with measurements obtained using an anterior segment optical coherence tomography (AS-OCT) imaging system. Design: Observational cross-sectional study. Participants: Fifty eyes from 50 healthy subjects were recruited. Methods: CCT, CAC D, and ACV were measured. Subjects were re-examined twice within a week of the first measurements. Intrasession and intersession within-subject SD (S-w), precision (1.96 x S-w), coefficient of variation (CVw: 100 x S-w / overall mean), and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility. Bland Altman plots were used to assess agreements between Pentacam and AS-OCT measurements. Results: For intrasession repeatability, and ICC values were 0.78 and 0.98 for CCT, 0.92 and 0.99 for CACD, and 3.52 and 0.98 for ACV, respectively. For intersession repeatability, and ICC values were 1.19 and 0.96 for CCT, 1.25 and 0.99 for CACD, and 3.96 and 0.96 for ACV, respectively. The AS-OCT CCT measurement (519.23 [SD 34.37] mu m) was 18.53 mu m less than the Pentacam measurement (537.76 [SD 3 1.84] mu m). The Pentacam CACD measurement (3.03 [SD 0.32] mm) was 0.08 less than the AS-OCT measurement (3.11 [SD 0.31] mu m). The Pentacam ACV measurement (165.56 [SD 34.86] mu L) was 14.21 mu L less than the AS-OCT measurement (179.77 [SD 34.57] mu L). Conclusions: Although the Pentacam measurements of the anterior segment parameters were reliable, their agreement with the AS-CICT measurements was not sufficient.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2009]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2008]版:
Q4 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2008版] 出版当年五年平均 出版前一年[2007版] 出版后一年[2009版]

第一作者:
第一作者机构: [1]Capital Med Univ, Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Tongren Eye Ctr, Beijing 100730, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)