Reproducibility of RTVue retinal nerve fiber layer thickness and optic nerve head measurements in normal and glaucoma eyes

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ 中华系列

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Tongren Eye Ctr, Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
出处:
ISSN:

关键词: diagnostic techniques ophthalmological instrumentation optical coherence tomography standards reproducibility

摘要:
Background RTVue spectral-domain optical coherence tomography (OCT) is a new, ultra high-speed and high-resolution instrument, potentially to measure the presence of glaucoma or its progression accurately. The objective of this study was to evaluate its reproducibility of retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) measurements in normal and glaucoma eyes. Methods This study was an observational clinical study. One eye was selected randomly from each of 89 normal individuals and 63 glaucoma patients in a range of severity. RNFL thickness and ONH were measured 3 times on the same day to determine intrasession variability. The same instrument was used by the same operator for all scans. lntrasession within-subject standard deviation (Sw), precision (1.96xSw), coefficient of variation (CVw, 100xSw/overall mean), and intraclass coefficient (ICC) were calculated to evaluate reproducibility. Results RTVue OCT demonstrated double hump patterns in the RNFL profiles. High reproducibility was observed in all ONH parameters. For normal eyes, the value of ICC ranged between 0.98 and 1.00. For eyes with different extent of glaucoma, it ranged between 0.94 and 1.00. High reproducibility was also observed in RNFL thickness measurements. The values of ICC for averaged RNFL thickness ranged between 0.95 and 1.00 in all cases. For regional parameters, it ranged from 0.94 to 0.98 for normal eyes, 0.94 to 1.00 for mild glaucoma eyes, 0.87 to 1.00 for moderate glaucoma eyes, and 0.77 to 0.97 for severe glaucoma eyes. The nasal regions of severe glaucoma appeared to be most variable, as nasal lower region and inferior nasal region had the ICC values of 0.77 and 0.87. Conclusion Reproducibility of RTVue RNFL and ONH measurements was excellent in normal and glaucoma groups. Chin Med J 2010;123(14):1898-1903

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2009]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2008]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2008版] 出版当年五年平均 出版前一年[2007版] 出版后一年[2009版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Tongren Eye Ctr, Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)