高级检索
当前位置: 首页 > 详情页

Using machine learning to predict post-operative depth of focus after cataract surgery with implantation of Tecnis Symfony.

文献详情

资源类型:
Pubmed体系:
机构: [1]Cataract Department, Daqing Oilfield General Hospital, Daqing City, Heilongjiang, China [2]Medical Device Epidemiology, Johnson & Johnson, New Brunswick, NJ, USA [3]Medical and Clinical Affairs, Johnson & Johnson, Beijing, China [4]Mu Sigma, Bangalore, India [5]Health Economic Research Institute, Sun Yat-sen University, Guangzhou, China [6]Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH, USA
出处:
ISSN:

关键词: Lens/cataract epidemiology/biostatistics IOLs biometry/axial length secondary IOL implantation

摘要:
To predict post-operative depth of focus (DoF) using machine learning techniques after cataract surgery with Tecnis Symfony implantation and determine associated impact factors.This was a retrospective cohort study among patients receiving Tecnis Symfony implantation, an extended-range-of-vision intraocular lens, during October 2016-January 2020 at Daqing Oilfield General Hospital, China. Four different predictive models were used to predict good post-operative DoF (⩾2.5 D): Extreme Gradient Boost (XGBoost), random forest (RF), LASSO penalized regression, and multivariable logistic regression (MLR). Apriori algorithm was employed to further explore the association between patient attributes and DoF.A total of 182 unique cases (143 patients) were included. The XGBoost model produced the best predictive accuracy compared to RF, LASSO, and MLR models. Overall performance of the best fitting XGBoost model was as follows: accuracy = 70.3%, AUC = 80.2%, sensitivity = 65.5%, and specificity = 87.5%. The Apriori algorithm identified six preoparative attributes with substantial effects on good post-operative DoF: low anterior chamber depth (ACD) (1.9 to <2.5 mm), smaller pupil size (1.7 to <2.5 mm), low-to-mid axial length (21 to <23 mm), minimum astigmatism degree (-0.2 to 0 diopter), low IOP (9 to <12 mmHg), and medium lens target refractive error (-0.5 to <-0.25 diopter).Machine Learning models were able to predict good post-operative DoF among cataract patients receiving a Tecnis Symfony ocular lens implantation. The accuracy of the model was above 70%. The Apriori algorithm identified six preoperative attributes with a strong association with post-operative DoF.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
第一作者:
第一作者机构: [1]Cataract Department, Daqing Oilfield General Hospital, Daqing City, Heilongjiang, China
通讯作者:
通讯机构: [2]Medical Device Epidemiology, Johnson & Johnson, New Brunswick, NJ, USA [*1]Medical Device Epidemiology, Johnson & Johnson Co., 410 George Street, New Brunswick, NJ 08901, USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25491 今日访问量:0 总访问量:1499 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)