高级检索
当前位置: 首页 > 详情页

Circulating E3 ligases are novel and sensitive biomarkers for diagnosis of acute myocardial infarction

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Chaoyang Hosp, Dept Cardiol,Beijing AnZhen Hosp,Key Lab Remodeli, Dept Physiol Pathol & Pathophysiol,Sch Basic Med, Beijing 100069, Peoples R China [2]Shanxi Prov Peoples Hosp, Dept Cardiol, Taiyuan 030012, Peoples R China [3]Capital Med Univ,Beijing Tiantan Hosp,Dept Cardiol,Beijing 100050,Peoples R China [4]Capital Med Univ, Beijing Xuanwu Hosp, Dept Cardiol, Beijing 100053, Peoples R China [5]Dalian Med Univ, Affiliated Hosp 1, Inst Cardiovasc Dis, Dept Cardiol, Dalian 116011, Peoples R China
出处:
ISSN:

关键词: DEPENDENT CARDIAC-HYPERTROPHY UBIQUITIN-PROTEASOME SYSTEM QT INTERVAL DURATION TROPONIN-I COMMON VARIANTS MYOGLOBIN HEART

摘要:
Ubiquitin ligase (E3) is a decisive element of the ubiquitin-proteasome system (UPS), which is the main pathway for intracellular protein turnover. Recently, circulating E3 ligases have been increasingly considered as cancer biomarkers. In the present study, we aimed to determine if cardiac-specific E3 ligases in circulation can serve as novel predictors for early diagnosis of acute myocardial infarction (AMI). By screening and verifying their tissue expression patterns with microarray and real-time PCR analysis, six of 261 E3 ligases, including cardiac-specific Rnf207 and cardiac-and muscle-enriched Fbxo32/atrogin-1, Trim54/MuRF3, Trim63/MuRF1, Kbtbd10/KLHL41, Asb11 and Asb2 in mouse heart, were selected for the present study. In the AMI rats, the levels of five E3 ligases including Rnf207, Fbxo32, Trim54, Trim63 and Kbtbd10 in the plasma were significantly increased compared with control animals. Especially, the plasma levels of Rnf207 was markedly increased at 1 h, peaked at 3 h and decreased at 6-24 h after ligation. Further evaluation of E3 ligases in AMI patients confirmed that plasma Rnf207 level increased significantly compared with that in healthy people and patients without AMI, and showed a similar time course to that in AMI rats. Simultaneously, plasma level of cardiac troponin I (cTnI) was measured by ELISA assays. Finally, receiver operating characteristic (ROC) curve analysis indicated that Rnf207 showed a similar sensitivity and specificity to the classic biomarker troponin I for diagnosis of AMI. Increased cardiac-specific E3 ligase Rnf207 in plasma may be a novel and sensitive biomarkers for AMI in humans.

基金:

基金编号: 81025001 81330003 81228006 2014DFA31930 T2011160

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 医学
小类 | 2 区 医学:研究与实验
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 医学:研究与实验
JCR分区:
出版当年[2013]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Chaoyang Hosp, Dept Cardiol,Beijing AnZhen Hosp,Key Lab Remodeli, Dept Physiol Pathol & Pathophysiol,Sch Basic Med, Beijing 100069, Peoples R China
通讯作者:
通讯机构: [*1]Dalian Med Univ, Affiliated Hosp 1, Inst Cardiovasc Dis, Dept Cardiol, Dalian 116011, Peoples R China [5]Dalian Med Univ, Affiliated Hosp 1, Inst Cardiovasc Dis, Dept Cardiol, Dalian 116011, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)