高级检索
当前位置: 首页 > 详情页

Utilizing fundus images captured by two ultra-wide field imaging systems to measure diagnostic indicators and assess the grade of diabetic retinopathy

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ophthalmology, Peking University People's Hospital, Beijing, China. [2]Beijing Key Laboratory of Ocular Disease and Optometry Science, Beijing, China. [3]Xiamen Eye Center of Xiamen University, Xiamen, China. [4]Henan Provincial People's Hospital, Zhengzhou, China. [5]Henan Eye Hospital, Zhengzhou, China. [6]People's Hospital of Zhengzhou University, Zhengzhou, China. [7]People's Hospital of Henan University, Zhengzhou, China. [8]Eye Institute of Shandong First Medical University, Eye Hospital of Shandong, Medical University (Shandong Eye Hospital), Jinan, China. [9]State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Jinan, China. [10]School of Ophthalmology, Shandong First Medical University, Jinan, China.
出处:

关键词: Diabetic retinopathy Ultra-wide-field retinal imaging systems Early treatment of diabetic retinopathy study diabetic retinopathy severity International clinical diabetic retinopathy severity Chinese clinical diagnosis and treatment guidelines for diabetic retinopathy

摘要:
This study compared the effectiveness of different ultrawide field fundus imaging systems (Clarus™ 500 and Optos®) in diagnosing diabetic retinopathy (DR).This was a prospective, multicentre study. Retinal photographs were captured at four eye centres utilizing both the Clarus™ 500 and Optos® imaging systems. The image quality and the effective retinal area were compared. Then the consistency in diagnosing the severity of DR by two distinct imaging systems was compared according to three separate grading criteria (the International Council of Ophthalmology, the Early Treatment Diabetic Retinopathy Study [ETDRS] grading diagnostic criteria, and the Chinese Clinical Diagnosis and Treatment Guidelines for Diabetic Retinopathy [2014]) were analysed.A total of 113 patients, 201 eyes and 402 images were included in this study. 39 images were excluded due to the poor image quality and 363 images were finally analyzed. The Clarus™ imaging system demonstrated better image quality than the Optos® imaging system (κ = 0.195). The mean effective retinal area was 490.03 ± 112.33 Disc area(DA) in the Clarus™ group and 410.41 ± 92.12 DA in the Optos® group (P = 0.000). The κ values were 0.812 for ETDRS DR severity, 0.787 for ICO DR severity, and 0.790 for the Chinese guidelines, indicating substantial agreement between the two imaging systems. However, Clarus™ indicated higher DR severity than the Optos® imaging system, with a higher detection rate of intraretinal microvascular abnormalities (IRMAs) and neovascularization.Clarus™ and Optos® exhibit strong concordance in the identification of DR. Clarus™ offers better image quality and IRMA recognition than Optos® and better identifies patients who need treatment.© 2024. The Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
第一作者:
第一作者机构: [1]Department of Ophthalmology, Peking University People's Hospital, Beijing, China. [2]Beijing Key Laboratory of Ocular Disease and Optometry Science, Beijing, China.
通讯作者:
通讯机构: [1]Department of Ophthalmology, Peking University People's Hospital, Beijing, China. [2]Beijing Key Laboratory of Ocular Disease and Optometry Science, Beijing, China. [3]Xiamen Eye Center of Xiamen University, Xiamen, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23465 今日访问量:6 总访问量:1282 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)