高级检索
当前位置: 首页 > 详情页

Thin minimal rim width at Bruch's membrane opening is associated with glaucomatous paracentral visual field loss

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ ESCI

机构: [1]Department of Ophthalmology, Harvard Medical School, Massachusetts Eye and Ear, Boston, MA, 2Boston Keratoprosthesis Laboratory, Massachusetts Eye and Ear – Schepens Eye Research Institute, Harvard Medical School, Boston, MA, USA [3]Department of Ophthalmology, Universidade Federal de São Paulo, São Paulo, Brazil [4]Department of Ophthalmology, Beijing China-Japan Friendship Hospital, Beijing, People’s Republic of China [5]Department of Ophthalmology, David Geffen School of Medicine and S Stein Eye Institute, Los Angeles, CA, USA [6]Channing Division of Network Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard
出处:
ISSN:

关键词: paracentral loss BMO-MRW open angle glaucoma optic nerve damage swept-source OCT

摘要:
Purpose: To compare optic nerve head (ONH) measurements in glaucomatous eyes with paracentral visual field (VF) loss to eyes with peripheral VF loss and controls. Methods: Open-angle glaucoma (OAG) patients with early paracentral VF loss or isolated peripheral VF loss as well as control subjects underwent ONH imaging with swept-source optical coherence tomography (OCT) and retinal nerve fiber layer (RNFL) imaging with spectral-domain OCT. Minimum rim width at Bruch's membrane opening (BMO-MRW), lamina cribrosa depth (LCD), and RNFL thickness were compared among the glaucoma and control groups with one-way analysis of variance, Kruskal-Wallis test, and multiple regression analysis. Results: Twenty-nine eyes from 29 OAG patients (15 early paracentral and 14 isolated peripheral VF loss) and 20 eyes of 20 control subjects were included. The early paracentral and isolated peripheral VF loss groups had similar VF mean deviation (MD) (-5.3 +/- 2.7 dB and -3.7 +/- 3.0 dB, p=0.15, respectively). Global BMO-MRW was lower in OAG eyes than in controls (193.8 +/- 40.0 vs 322.7 +/- 62.2 mu m, p<0.001), but similar between eyes with early paracentral VF loss and those with isolated peripheral VF loss (187.6 +/- 43.4 vs 200.6 +/- 36.3 mu m; p>0.99). In contrast, the minimal BMO-MRW was lower in eyes with early paracentral loss (69.0 +/- 33.6 mu m) than in eyes with isolated peripheral loss (107.7 +/- 40.2 mu m; p=0.03) or control eyes (200.1 +/- 40.8 mu m; p<0.001). Average and thinnest RNFL thickness did not differ between OAG groups (p=0.61 and 0.19, respectively). Horizontal and vertical LCD did not differ among the OAG groups and controls (p=0.80 and 0.82, respectively). Multivariable linear regression analysis among OAG cases confirmed the association between lower minimal BMO-MRW and early paracentral VF loss (beta=-38.3 mu m; 95% confidence interval, -69.8 to -6.8 mu m; p=0.02) after adjusting for age, gender, MD, and disc size. Conclusion: Thin minimal BMO-MRW may represent a new structural biomarker associated with early glaucomatous paracentral VF loss.

基金:
语种:
被引次数:
WOS:
PubmedID:
JCR分区:
出版当年[2015]版:
最新[2023]版:
Q3 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版]

第一作者:
第一作者机构: [1]Department of Ophthalmology, Harvard Medical School, Massachusetts Eye and Ear, Boston, MA, 2Boston Keratoprosthesis Laboratory, Massachusetts Eye and Ear – Schepens Eye Research Institute, Harvard Medical School, Boston, MA, USA [3]Department of Ophthalmology, Universidade Federal de São Paulo, São Paulo, Brazil
通讯作者:
通讯机构: [1]Department of Ophthalmology, Harvard Medical School, Massachusetts Eye and Ear, Boston, MA, 2Boston Keratoprosthesis Laboratory, Massachusetts Eye and Ear – Schepens Eye Research Institute, Harvard Medical School, Boston, MA, USA [*1]Department of Ophthalmology, Harvard Medical School, Massachusetts Eye and Ear, 243 Charles St, Boston, MA02114, USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)