高级检索
当前位置: 首页 > 详情页

Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction

| 认领 | 导出 |

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Chinese Peoples Liberat Army Gen Hosp, Dept Orthoped, Beijing, Peoples R China [2]Nankai Univ, Med Sch, Tianjin, Peoples R China [3]Capital Med Univ,Beijing Tongren Hosp,Dept Orthoped,Beijing,Peoples R China
出处:
ISSN:

关键词: Anterior cruciate ligament reconstruction Biomechanics Cortical allograft bone Absorbable interference screw

摘要:
OBJECTIVE: To compare the mechanical behavior of a novel bioabsorbable cortical interference screw (BCIS) with bioabsorbable interference screw (BIS; Polylactate hydroxyapatite) used for anterior cruciate ligament (ACL) reconstruction in femoral and tibial fixation with doubled Achilles tendon graft in vitro. PATIENTS AND METHODS: 30 paired goat knee specimens were harvested from 15 male sheep aged 18 months. All soft tissues were stripped from the bones of 20 paired specimens, and the last 10 paired specimens were stripped all soft tissues besides ACL (femur-ACL-tibia complex). The Achilles tendon was harvested as graft for ACL reconstruction. The specimens were divided into several groups: BCIS femoral fixation (group A, n=10), BIS femoral fixation (group B, n=10), BCIS tibial fixation (group C, n=10), BIS tibial fixation (group D, n=10), Group E is femur-ACL-tibia complex (n=10). Cyclic loading test was performed from 50 to 250 N at 1 Hz for 1000 cycles and followed by a load-to-failure test at 25 mm/sec. A paired t-test was used to compare the biomechanical properties of group A, B, E and group C, D, E. RESULTS: No fixation structures failed during the cyclic phase. Cyclic displacement for group B was superior to group A, and showed statistically significant difference after 30, 100, 500, 1000 cycles. Group E got minimum cyclic displacements compared with group A and group B, and showed statistically significant difference after 500, 1000 cycles compared with group A. Cyclic displacement for group D was superior to group C, and showed statistically significant difference after 100, 500, 1000 cycles. Group E got minimum cyclic displacements compared with group C and group D, and showed statistically significant difference after 500,1000 cycles compared with group C. Regarding MFL, group A was superior to group B (572.10 +/- 111.12 N vs. 413.96 +/- 34.56 N, p=0.118), group E was superior to group A (599.74 +/- 85.45N vs. 572.10 +/- 111.12 N, p=0.992), and group C was superior to group D (802.88 +/- 240.07 N vs. 415.63 +/- 51.9 N, p<0.001), group C was superior to group E 802.88 +/- 240.07 N vs. 599.74 +/- 85.45 N, p=0.024). Regarding YL, group A was superior to group B (521.57 +/- 93.96 N vs. 366.99 +/- 44.66 N, p=0.109), group E was superior to group A (565.37 +/- 66.05 N vs. 521.57 +/- 93.96 N, p=0.952), and group C was superior to group D (735.63 +/- 242.91 N vs. 394.49 +/- 31.90 N, p<0.001), group C was superior to group E (735.63 +/- 242.91 N vs. 565.37 +/- 66.05 N, p=0.063). Regarding stiffness, group A was superior to group B (157.36 +/- 34.31 N/mm vs. 91.98 +/- 25.57 N/mm, p=0.001), group E was superior to group A (181.35 +/- 25.42 N vs. 157.36 +/- 34.31 N/mm, p=0.529), and group C was superior to group D (175.28 +/- 43.19 N/mm vs. 128.24 +/- 18.92 N/mm, p=0.032), group E was superior to group C (181.35 +/- 25.42 N/mm vs. 175.28 +/- 43.19 N/mm, p=0.995). CONCLUSIONS: In vitro, this experimental study suggested the biomechanical properties of novel bioabsorbable cortical interference screw (BCIS) were superior to bioabsorbable interference screw (BIS) used for femoral and tibial anterior cruciate ligament (ACL) reconstruction in a goat knee model.

基金:

基金编号: 2015AA020315

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 药学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 药学
JCR分区:
出版当年[2016]版:
Q3 PHARMACOLOGY & PHARMACY
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Chinese Peoples Liberat Army Gen Hosp, Dept Orthoped, Beijing, Peoples R China [2]Nankai Univ, Med Sch, Tianjin, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:21169 今日访问量:0 总访问量:1219 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题