机构:[1]Capital Univ Med Sci, Beijing Tongren Hosp, Tongren Eye Ctr, Beijing 100730, Peoples R China首都医科大学附属北京同仁医院首都医科大学附属同仁医院[2]Capital Univ Med Sci, Dept Ophthalmol, China Japan Fiendship Hosp, Beijing 100730, Peoples R China[3]Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
Purpose: To study the associations between changes in pupil diameter and in the anterior chamber angle configuration during the dark room provocative test. Methods: The study included 70 suspects of primary angle closure (study group) and 40 normal participants (control group). Using anterior-segment optical coherence tomography (AS-OCT), we measured the anterior chamber angle configuration and pupil diameter at 3 minutes and at 1.5 hours of dark adaptation. Results: In the study group, the mean number of closed angle segments was significantly (P < 0.001) higher at 3 minutes of dark adaptation (3.9 +/- 2.3) than at room light conditions (2.6 +/- 2.2) or at 1.5 hours of dark adaptation (3.1 +/- 2.1), with no statistically significant (P > 0.05) difference between the 2 latter values. In the study group, the pupil diameter was significantly associated with the number of closed angle segments at 3 minutes of dark adaptation (P < 0.01), but not at 1.5 hours of dark adaptation (P = 0.13). Defined as an increased number of closed angle segments, the dark room test was positive in a significantly higher number of participants at 3 minutes than at 1.5 hours of dark adaptation [44 (63%) eyes vs. 31 (44%) eyes; P < 0.05]. Final interocular pressure was statistically better correlated with the angle configuration segments assessed at 3 minutes (correlation coefficient r(2) = 0.33) than at 1.5 hours of dark adaptation (r(2) = 0.21). Conclusions: After short-term dark adaptation of 3 minutes, the assessment of the anterior chamber angle configuration by AS-OCT is more reliable than as if carried out after a long-term dark adaptation and may be used to identify suspects of primary angle closure.
基金:
Ministry of Science and Technology of the People's Republic of ChinaMinistry of Science and Technology, China [2007BAI18B08]
第一作者机构:[1]Capital Univ Med Sci, Beijing Tongren Hosp, Tongren Eye Ctr, Beijing 100730, Peoples R China[2]Capital Univ Med Sci, Dept Ophthalmol, China Japan Fiendship Hosp, Beijing 100730, Peoples R China
通讯作者:
通讯机构:[1]Capital Univ Med Sci, Beijing Tongren Hosp, Tongren Eye Ctr, Beijing 100730, Peoples R China[*1]Capital Univ Med Sci, Beijing Tongren Hosp, Tongren Eye Ctr, 2 Chongnei St, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
Li Dejiao,Wang Ningli,Wang Bingsong,et al.Correlation Between Pupil Diameter and Angle Configuration in the Dark Room Provocative Test[J].JOURNAL OF GLAUCOMA.2011,20(6):331-335.doi:10.1097/IJG.0b013e3181eda73a.
APA:
Li, Dejiao,Wang, Ningli,Wang, Bingsong,Wang, Tao,Li, Shuning...&Mu, Dapeng.(2011).Correlation Between Pupil Diameter and Angle Configuration in the Dark Room Provocative Test.JOURNAL OF GLAUCOMA,20,(6)
MLA:
Li, Dejiao,et al."Correlation Between Pupil Diameter and Angle Configuration in the Dark Room Provocative Test".JOURNAL OF GLAUCOMA 20..6(2011):331-335