高级检索
当前位置: 首页 > 详情页

Single-step Transepithelial photorefractive keratectomy in the treatment of mild, moderate, and high myopia: six month results.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ophthalmology, Peking University International Hospital, Beijing, China. [2]Tianjin Medical University Eye hospital, Tianjin Medical University Eye Institute, School of Optometry and Ophthalmology, Tianjin, China. [3]Department of Ophthalmology, Peking University People’s Hospital, Xizhimen South Street 11, Xi Cheng District, Beijing 100044, China.
出处:

关键词: Transepithelial photorefractive keratectomy Myopia TransPRK

摘要:
To evaluate the safety, efficacy, and the refractive outcomes of single-step transepithelial photorefractive keratectomy (TransPRK) for the correction of mild, moderate, and high myopia.This study consecutively recruited 32 high myopic eyes, 32 mild myopic and 32 moderate myopic eyes. Eyes with myopia that had undergone TransPRK treatment. Pre- and post-operative visual and refractive data, corneal Higher Order Aberration (HOA) as well as safety and efficacy indices were analyzed at 6 months postoperatively.Six months after TransPRK, the manifest refraction spherical equivalent (SE) was not significantly between high myopia group and moderate myopia group (p = 0.636). No eyes lost ≥2 lines of corrected distant visual acuity (CDVA) in high myopic eyes. The uncorrected distance visual acuity (UDVA) was significantly higher in low and moderate myopia groups than the high myopia group (P < 0.001; P = 0.002). The CDVA was not significantly different between moderate and high myopia groups (P = 0.057). There was no significant difference in mean safety index between high myopia group (1.01 ± 0.14) and mild myopia group (1.08 ± 0.15) (P > 0.05). The mean safety index was significantly higher in the moderate myopia group (1.16 ± 0.23) than in the high myopia group (1.01 ± 0.14) (P = 0.002). The efficacy index was significantly higher in the moderate myopia group (1.05 ± 0.20) than in the high myopia group (0.89 ± 0.17) (P = 0.02), and there was no significant difference between the high myopia group (0.89 ± 0.17) and the low myopia group (0.96 ± 0.16) (P = 0.14).The mean safety index was over 1.0 in the three groups. TransPRK showed acceptable safety and efficacy in the moderate myopic eyes, as well as mild and high myopic eyes. High myopic eyes got very similar refractive results with moderate myopic eyes six months postoperatively. The safety and efficacy indexes were not significantly different between the high myopia group and the low myopia group.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 眼科学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
第一作者:
第一作者机构: [1]Department of Ophthalmology, Peking University International Hospital, Beijing, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:25498 今日访问量:0 总访问量:1499 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)