Corneal biomechanical properties and potential influencing factors in varying degrees of myopia

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China [2]Chengdu Univ TCM, Eye Coll, Chengdu, Sichuan, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing, Peoples R China
出处:
ISSN:

关键词: Varying degrees of myopia Corneal biomechanical properties Corvis ST Axial length Spherical equivalent

摘要:
To compare the corneal biomechanical parameters measured by Corvis ST in subjects with varying degrees of myopia. And the factors that may affect corneal biomechanical properties were also investigated. Participants in this prospective cross-sectional study were classified into three groups according to spherical equivalent (SE) and axial length (AL): Non-myopia (NM, SE > - 0.50 D and AL < 26 mm), Mild-to-moderate myopia (MM, - 6.00 D < SE <= - 0.50 D and AL < 26 mm), high myopia (HM, SE <= - 6.00 D or AL >= 26 mm). Ten corneal biomechanical parameters were finally included. Linear mixed-effects model accounting for using both eyes in the same participant was carried out to evaluate how the corneal biomechanical parameter was influenced by varying degrees of myopia after adjusting for biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT). Further, multiple linear regression was performed to explore the correlation between corneal biomechanical parameter and SE, AL, bIOP or CCT. A total of 304 eyes from 224 healthy myopic subjects were recorded. There were 95 eyes with NM, 122 eyes with MM, and 87 eyes with HM. After adjusting for bIOP and CCT, eyes with high myopia showed shorter highest concavity time (HC-time, p = 0.025), greater peak distance (PD, p = 0.001), greater deflection amplitude (DA-Max, p = 0.002), smaller whole eye movement (WEM-Max, p < 0.001) and reduced stiffness parameter (SP-A1, p < 0.001). Multiple regression analysis showed that five parameters (HC-time, p < 0.001; PD, p < 0.001; DA-Max, p = 0.001; WEM-Max, p < 0.001; and SP-A1, p < 0.001) of Corvis ST were significantly correlated with AL, and one parameter (Corvis biomechanical index, p = 0.016) has significant relationship with SE. With the increase of myopia, significant changes in several corneal biomechanical parameters indicated a progressive decrease in corneal stiffness, independent of bIOP and CCT. Corneal biomechanical parameters may be predictors of scleral mechanical strength in high myopia, which has certain application value in clinical management of myopia.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 综合性期刊
小类 | 2 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2022]版:
Q2 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:23425 今日访问量:5 总访问量:1281 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学附属北京同仁医院 技术支持:重庆聚合科技有限公司 地址:北京市东城区东交民巷1号(100730)